Robert - thank you so much for pointing me to this bug. I have put a
comment asking if there is a timeframe to expect this fix in icehouse.

On Mon, Dec 1, 2014 at 2:17 AM, Robert van Leeuwen <
[email protected]> wrote:

>  >I noticed QOS in general is not working.
> > Btw, I am using latest icehouse devstack and testing this on a mapped
> rbd device. Please, advise.
>
> There lies the problem, throttling is not working for ceph devices in
> Icehouse. ( images_type=rbd )
> This is fixed in Juno but was never back-ported.
> The bug report is here: https://bugs.launchpad.net/nova/+bug/1362129
>
> Cheers,
> Robert van Leeuwen
>
_______________________________________________
Mailing list: http://lists.openstack.org/cgi-bin/mailman/listinfo/openstack
Post to     : [email protected]
Unsubscribe : http://lists.openstack.org/cgi-bin/mailman/listinfo/openstack

Reply via email to