2013.07.18. 18:27 keltezéssel, Nikolay Martynov írta:
> Looks like trunk@37090 has changed the logic that determines if router's 
> button was pressed. This resulted in TEW632BRP always booting into failsafe 
> mode because it detected pressed button (which was not pressed).
> 
> Measure with voltmeter has shown that buttons on this router are actually 
> active-low. This patch reflects this fact in board configuration and fixes 
> 'load info failsafe mode' issue.
> 
> Note: it looks like Trendnet TEW632BRP and a close relative to TEW-652BRP 
> V1.0 and D-Link DIR-615C1, so same problem may exist on those routers as 
> well. This patch doesn't affect routers other than 632BRP and unfortunately I 
> do not have hardware to test this issue with other routers.
> 
> This patch fixes #13893 and is tested on actuall Trendnet TEW632BRP.
> 
> Signed-off-by: Nikolay Martynov <[email protected]>

Applied.

Thanks,
Gabor