2013.07.18. 18:27 keltezéssel, Nikolay Martynov írta: > Looks like trunk@37090 has changed the logic that determines if router's > button was pressed. This resulted in TEW632BRP always booting into failsafe > mode because it detected pressed button (which was not pressed). > > Measure with voltmeter has shown that buttons on this router are actually > active-low. This patch reflects this fact in board configuration and fixes > 'load info failsafe mode' issue. > > Note: it looks like Trendnet TEW632BRP and a close relative to TEW-652BRP > V1.0 and D-Link DIR-615C1, so same problem may exist on those routers as > well. This patch doesn't affect routers other than 632BRP and unfortunately I > do not have hardware to test this issue with other routers. > > This patch fixes #13893 and is tested on actuall Trendnet TEW632BRP. > > Signed-off-by: Nikolay Martynov <[email protected]>
Applied. Thanks, Gabor _______________________________________________ openwrt-devel mailing list [email protected] https://lists.openwrt.org/cgi-bin/mailman/listinfo/openwrt-devel