On Fri, 2014-06-20 at 11:49 +0200, Andreas Lauser wrote: > [i]f MULTX- is not specified, do the values specified in MULTX also > apply for the negative direction?
No, they do not. If MULTX- is not explicitly defined in the input, the format requires that MULTX- be implicitly assigned an all-ones array. In other words, the multiplier in this case is exactly equal to the MULTX value of the connection's "left" cell. Bård _______________________________________________ Opm mailing list [email protected] http://www.opm-project.org/mailman/listinfo/opm