Hi,
Please see inline.
Thanks,
john

> -----Original Message-----
> From: dev [mailto:dev-boun...@dpdk.org] On Behalf Of Thomas F Herbert
> Sent: Tuesday, October 18, 2016 1:35 PM
> To: d...@dpdk.org
> Cc: Keith Burns <alaga...@gmail.com>; Edward Warnicke
> <hagb...@gmail.com>; opnfv-tech-discuss@lists.opnfv.org
> Subject: [dpdk-dev] [opnfv-tech-discuss][apex][ovsnfv]Problem showed up
> with OVS/DPDK with Cisco VIC adapter
> 
> All:
> 
> This is not necessarily related to VPP but rather to OVS/DPDK.
> In OPNFV we found the following problem when using UCS NIC.
> The UCS fabric seems to set a VLAN tag on untagged packets.
> Any thoughts from DPDK and VPP folks would be appreciated.
> 
In a UCS fabric, all frames between the VIC and the Fabric Interconnect will be 
tagged. This is required to carry both VLAN information and, being a converged 
adapter supporting both Ethernet and FCoE, traffic class. For non-UCS fabric 
deployments, there is currently no way to turn off egress priority tagging on 
the VIC adapter. If a packet being sent from DPDK to the enic PMD is priority 
tagged (VLAN=0) or has no VLAN tag, the default VLAN tag (as set up in 
CIMC/UCSM manager) will be inserted.  This should only be an issue with 
C-series UCS servers connected point to point or through a switch that can't 
cope with priority tags. Is that the case here?

> ...
> --
> *Thomas F Herbert*
> SDN Group
> Office of Technology
> *Red Hat*
_______________________________________________
opnfv-tech-discuss mailing list
opnfv-tech-discuss@lists.opnfv.org
https://lists.opnfv.org/mailman/listinfo/opnfv-tech-discuss