Hi BJ,

> 119.7.2 is wrong. It should state 32 like 119.2. OSGi has released an
> errata on this.

Thanks.  (How badly will my reputation suffer if I propose "erratum" as a
corrigendum for "errata"?)

Vale

Chris

> From:   chris.g...@k-embedded-java.com
> To:     "OSGi Developer Mail List" <osgi-dev@mail.osgi.org>,
> Date:   2011/11/17 07:02
> Subject:        [osgi-dev] Monitorable PID length
> Sent by:        osgi-dev-boun...@mail.osgi.org
>
>
>
> Hi there,
>
> In 119.2 compendium, Version 4.2 I read that the length of the
> monitorable-pid "must fit in 32 bytes when UTF-8 encoded".  (Given that
> all the characters allowed in the symbolic-name syntax encode as one byte,
> this would appear to mean that the length is limited to 32 characters).
>
> However in 119.7.2 it is stated that "The length of the PID must not
> exceed 20 characters".  Am I missing something, or is there an
> inconsistency here?
>
> Best regards
>
> Chris Gray
>
>
> _______________________________________________
> OSGi Developer Mail List
> osgi-dev@mail.osgi.org
> https://mail.osgi.org/mailman/listinfo/osgi-dev
>
>
> _______________________________________________
> OSGi Developer Mail List
> osgi-dev@mail.osgi.org
> https://mail.osgi.org/mailman/listinfo/osgi-dev


_______________________________________________
OSGi Developer Mail List
osgi-dev@mail.osgi.org
https://mail.osgi.org/mailman/listinfo/osgi-dev

Reply via email to