No, i don't have. I have Pan + MS (fusioned in other software) and then i subset the data (and now trying to create reflectance TOA image).
With ReadImageInfo i can create .geom in original product and use to set metadata to the OpticalCalibration application? Thank you Grizonnet! Em quarta-feira, 6 de agosto de 2014 04h23min19s UTC-3, Grizonnet Manuel escreveu: > > Hi, > > if you subset your original image using OTB (for instance with the > ExtractROI application) it will create by default an ascii file with the > extension .geom. This file contains metadata info required to perform > orthorectification or optical calibration. > > You also create this .geom file with the original product and the > ReadImageInfo application. > > Do you have this .geom file with your subset? > > Best regards, > > Manuel > > Le 05/08/2014 19:23, José Guilherme Fronza a écrit : > > Hello to all. > > I'm trying to use Optical Calibration through Osgeo4W64 calling > otbgui_OpticalCalibration > I subset my original image (PMS Pleiades) and i don't have the dim file or > metadata. > I wanna put metadata file in parameter to correct the image to TOA > reflectance file. > > Can someone help me? > I know the parameters required to perform this application. > > I have the logical error msg: > > 2014 Aug 05 14:05:05 : Application.logger (FATAL) The following error > occurred during OTB-application execution: > c:\users\jmalik\dashboard\src\otb\code\io\otbOpticalDefaultImageMetadataInterface.h:63: > > itk::ERROR: OpticalDefaultImageMetadataInterface(0000000003CBBCF0): > GetPhysicalGain not implemented in OpticalDefaultImageMetadataInterface, no > captor type found > > > -- > -- > Check the OTB FAQ at > http://www.orfeo-toolbox.org/FAQ.html > > You received this message because you are subscribed to the Google > Groups "otb-users" group. > To post to this group, send email to [email protected] > <javascript:> > To unsubscribe from this group, send email to > [email protected] <javascript:> > For more options, visit this group at > http://groups.google.com/group/otb-users?hl=en > --- > You received this message because you are subscribed to the Google Groups > "otb-users" group. > To unsubscribe from this group and stop receiving emails from it, send an > email to [email protected] <javascript:>. > For more options, visit https://groups.google.com/d/optout. > > > -- > Manuel GRIZONNET > CNES - DCT/SI/AP - BPI 1219 > 18, avenue Edouard Belin > 31401 Toulouse Cedex 09 - France > Tel: +33 561 282 630 - Fax: +33 561 283 109 > > > -- -- Check the OTB FAQ at http://www.orfeo-toolbox.org/FAQ.html You received this message because you are subscribed to the Google Groups "otb-users" group. To post to this group, send email to [email protected] To unsubscribe from this group, send email to [email protected] For more options, visit this group at http://groups.google.com/group/otb-users?hl=en --- You received this message because you are subscribed to the Google Groups "otb-users" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. For more options, visit https://groups.google.com/d/optout.