Eric, The problem comes from ITK; developers obviously didn't plan negative spacingx values. Don't worry about reporting that bug, I'll do it myself.
Could you just output the result of ReadImageInfo within a txt file, and attach it to this post: I am intrigued to find out which projection system resulted in producing negative spacingx values. Thank you, Christophe. Le lundi 5 janvier 2015 17:36:25 UTC+1, Eric Wenger a écrit : > > Christophe, > > Thanks for your response. I just verified that these images do have a > negative spacingx value. Should I open a bug request? > > --Eric > > On Mon, Jan 5, 2015 at 9:55 AM, Christophe Palmann <[email protected] > <javascript:>> wrote: > >> Hi Eric, >> >> Could you use the ReadImageInfo application and check the status of the X >> spacing value for different situations ? >> >> It seems that negative values result in performing a test that >> compulsorily brings out this error message... >> >> Regards, >> Christophe. >> >> >> >> Le vendredi 2 janvier 2015 20:56:35 UTC+1, Eric Wenger a écrit : >> >>> I have a set of WorldView-2 images that I am converting from radiance to >>> reflectance using the otbcli_OpticalCalibration app. On some of my images >>> (10-20%) I get the following error. I have found some information about >>> this error via google but this one seems unique in that I am only >>> specifying one spatial area and it should be duplicated by the application >>> into an identical spatial area. Any idea how I can resolve this? >>> >>> --Eric >>> >>> d:\msi_retiling\PROCGREENTMP100>call otbcli_OpticalCalibration -in >>> 10SEP14002605 >>> -M1BS-500081197150_01_P008.NTF -level toa -ram 1024 -out >>> "10SEP14002605-M1BS-500 >>> 081197150_01_P008_TOAREF_FLOAT.TIF?&gdal:co:INTERLEAVE= >>> BAND&gdal:co:TILED=YES&gd >>> al:co:BLOCKXSIZE=256&gdal:co:BLOCKYSIZE=256" -progress 0 >>> >>> 2015 Jan 02 14:45:23 : Application.logger (INFO) >>> File: 10SEP14002605-M1BS-500081197150_01_P008.NTF >>> Sensor detected: WV02 >>> Parameters extract from input image: >>> Acquisition Day: 14 >>> Acquisition Month: 9 >>> Acquisition Year: 2010 >>> Acquisition Sun Elevation Angle: 42.6 >>> Acquisition Sun Azimuth Angle: 37.2 >>> Acquisition Viewing Elevation Angle: 76.7 >>> Acquisition Viewing Azimuth Angle: 152.2 >>> Acquisition gain (per band): 5.0884 4.3067 6.48611 7.33177 >>> 5.20105 8.657 >>> 11 8.07756 11.015 >>> Acquisition bias (per band): 0 0 0 0 0 0 0 0 >>> Solar Irradiance (per band): 1758.22 1974.24 1856.41 1738.48 >>> 1559.46 134 >>> 2.07 1069.73 861.287 >>> >>> 2015 Jan 02 14:45:23 : Application.logger (INFO) Compute Top of >>> Atmosphere re >>> flectance >>> 2015 Jan 02 14:45:23 : Application.logger (INFO) Clamp values between >>> [0, 100 >>> ] >>> 2015 Jan 02 14:45:23 : Application.logger (FATAL) The following error >>> occurre >>> d during application execution : c:\users\jmalik\dashboard\src\ >>> itkv4\modules\cor >>> e\common\include\itkImageToImageFilter.hxx:248: >>> itk::ERROR: ImageToLuminanceImageFilter(0000000003EE5560): Inputs do >>> not occupy >>> the same physical space! >>> InputImage Origin: [1.4601472e+002, -3.7257500e+001], InputImagePrimary >>> Origin: >>> [1.4601472e+002, -3.7257500e+001] >>> Tolerance: -2.0980286e-011 >>> InputImage Spacing: [-2.0980286e-005, 1.7159755e-005], InputImagePrimary >>> Spacing >>> : [-2.0980286e-005, 1.7159755e-005] >>> Tolerance: -2.0980286e-011 >>> >>> OTB OpticalCalibration failed for 10SEP14002605-M1BS- >>> 500081197150_01_P008 >>> >>> d:\msi_retiling\PROCGREENTMP100> >>> >> -- >> -- >> Check the OTB FAQ at >> http://www.orfeo-toolbox.org/FAQ.html >> >> You received this message because you are subscribed to the Google >> Groups "otb-users" group. >> To post to this group, send email to [email protected] >> <javascript:> >> To unsubscribe from this group, send email to >> [email protected] <javascript:> >> For more options, visit this group at >> http://groups.google.com/group/otb-users?hl=en >> --- >> You received this message because you are subscribed to the Google Groups >> "otb-users" group. >> To unsubscribe from this group and stop receiving emails from it, send an >> email to [email protected] <javascript:>. >> For more options, visit https://groups.google.com/d/optout. >> > > -- -- Check the OTB FAQ at http://www.orfeo-toolbox.org/FAQ.html You received this message because you are subscribed to the Google Groups "otb-users" group. To post to this group, send email to [email protected] To unsubscribe from this group, send email to [email protected] For more options, visit this group at http://groups.google.com/group/otb-users?hl=en --- You received this message because you are subscribed to the Google Groups "otb-users" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. For more options, visit https://groups.google.com/d/optout.