On 2/5/26 5:07 PM, Lorenzo Bianconi via dev wrote: > On Feb 04, Xavier Simonart via dev wrote: >> Both ovn-ic and ovn-northod were trying to update Service_Monitor options >> az-name, but their updates were differing by the _comment. >> This resulted in 100% CPU use by ovn-northd and ovn-ic. >> >> The test "Service Monitor synchronization" was hitting the issue, but was >> successful. The test has been updated to detect the issue and fail if the >> issue >> is still encountered. >>
Hi Xavier, This is not an actual review, just a note (maybe relevant only to us in Red Hat) that the Reported-at link is a bit off. >> Reported-at: https://issues.redhat.com/browse/FDP-2657 It should be: Reported-at: https://issues.redhat.com/browse/FDP-2672 Which is the "upstream" child of the FDP-2657 epic. >> Fixes: f40a5c3c803a ("ic: Implement cross-AZ service monitor >> synchronization.") >> Signed-off-by: Xavier Simonart <[email protected]> > > Acked-by: Lorenzo Bianconi <[email protected]> > Regards, Dumitru _______________________________________________ dev mailing list [email protected] https://mail.openvswitch.org/mailman/listinfo/ovs-dev