On 30 Sep 2020, at 13:19, Flavio Leitner wrote:

> On Wed, Sep 30, 2020 at 08:45:07AM +0200, Eelco Chaudron wrote:
>>
>>
>> On 29 Sep 2020, at 22:07, Flavio Leitner wrote:
>>
>>> When the number of flows in the datapath reaches twice the
>>> maximum, revalidators will delete all flows as an emergency
>>> action to recover. In that case, log a message with values
>>> and increase a coverage counter.
>>>
>>> Signed-off-by: Flavio Leitner <[email protected]>
>>> ---
>>
>> Other than the line being over 79 characters, see 0-day robot response, it
>> looks fine to me.
>
> I tried to break it in different ways but none looked
> better than what I posted to me. I am open to suggestions.

Looking at it, it’s not getting better ;) I would say leave it as is!

> Thanks for reviewing it!
> fbl
>
>>
>> Acked-by: Eelco Chaudron <[email protected]>
>>
>
> -- 
> fbl