On Thu, Nov 26, 2020 at 10:54 AM Ben Pfaff <b...@ovn.org> wrote: > > On Wed, Nov 25, 2020 at 01:13:22PM +0530, Numan Siddique wrote: > > On Wed, Nov 25, 2020 at 4:21 AM Ben Pfaff <b...@ovn.org> wrote: > > > > > > The tests "superseding ACLs with conjunction" and "ARP replies for SNAT > > > external ips" trigger bugs in the ovn-controller incremental processing > > > logic. This works around those bugs. > > > > > > > > Signed-off-by: Ben Pfaff <b...@ovn.org> > > > > Can you please try test case - "ARP replies for SNAT external ips" > > with the latest OVN master ? > > > > The commit > > https://github.com/ovn-org/ovn/commit/53f60c7ab742cba0b3dd84b73658e0bbd44ec145 > > should solve this issue. > > > > I will take a look into the other test case - "superseding ACLs with > > conjunction". > > It does solve the issues that this was meant to fix. > > The following tests still segfault in ovn-controlle: > > 269: ovn -- controller I-P handling with monitoring disabled -- > ovn-northd-ddlog FAILED (ovs-macros.at:253) > 301: ovn -- ovn-controller incremental processing FAILED > (ovn-performance.at:542) > > with backtraces that look like the following. If this is because of a > bug I introduced into ovsdb-idl, I think it has to be a subtle one... > > #0 0x0000000000413e00 in handle_deleted_lport (pb=0x110c550, > b_ctx_in=0x7ffea1c813d0, b_ctx_out=0x7ffea1c81380) > at ../controller/binding.c:1982 > #1 0x000000000041628e in binding_handle_port_binding_changes ( > b_ctx_in=b_ctx_in@entry=0x7ffea1c813d0, > b_ctx_out=b_ctx_out@entry=0x7ffea1c81380) at ../controller/binding.c:2153 > #2 0x0000000000434650 in runtime_data_sb_port_binding_handler ( > node=0x7ffea1c82730, data=0x10ad150) at > ../controller/ovn-controller.c:1471 > #3 0x00007f0016dff4ab in engine_compute (recompute_allowed=<optimized out>, > node=<optimized out>) at ../lib/inc-proc-eng.c:306 > #4 engine_run_node (recompute_allowed=true, node=0x7ffea1c82730) > at ../lib/inc-proc-eng.c:352 > #5 engine_run (recompute_allowed=recompute_allowed@entry=true) > at ../lib/inc-proc-eng.c:377 > #6 0x0000000000411a4d in main (argc=<optimized out>, argv=<optimized out>) > at ../controller/ovn-controller.c:2747
With your IDL CS patch series, I'm seeing 100% failure for "ovn-controller incremental processing" test case. I think ovn-controller should not segfault. Thanks for the backtrace. I will look into it. Thanks Numan > _______________________________________________ > dev mailing list > d...@openvswitch.org > https://mail.openvswitch.org/mailman/listinfo/ovs-dev > _______________________________________________ dev mailing list d...@openvswitch.org https://mail.openvswitch.org/mailman/listinfo/ovs-dev