On Thu, Feb 13, 2025 at 5:01 PM Xavier Simonart <[email protected]> wrote:

> Handle container ports migration in a similar way as vif migration.
> When a container port is migrated (i.e. when requested-chassis is
> configured
> for its parent port), install flows in both src and dst hypervisors.
> When migration completes, remove flows from src hypervisor.
>
> Reported-at: https://issues.redhat.com/browse/FDP-1037
>
> Signed-off-by: Xavier Simonart <[email protected]>
> ---
>

Hi Xavier,

thank you for the patch, I have a couple of comments down below.


 controller/binding.c  |  44 +++++---
>  controller/physical.c |   4 +-
>  tests/multinode.at    | 257 ++++++++++++++++++++++++++++++++++++++++++
>  tests/ovn.at          | 160 +++++++++++++++++++++++++-
>  4 files changed, 447 insertions(+), 18 deletions(-)
>
> diff --git a/controller/binding.c b/controller/binding.c
> index 7d4143008..7f1027b02 100644
> --- a/controller/binding.c
> +++ b/controller/binding.c
> @@ -1147,6 +1147,9 @@ set_pb_chassis_in_sbrec(const struct
> sbrec_port_binding *pb,
>                  VLOG_INFO("%s: Claiming %s", pb->logical_port,
> pb->mac[i]);
>              }
>              sbrec_port_binding_set_chassis(pb, chassis_rec);
> +            if (is_additional_chassis(pb, chassis_rec)) {
> +                remove_additional_chassis(pb, chassis_rec);
> +            }
>


This feels like a separate issue or am I missing something?

         }
>      } else if (!is_set) {
>          sbrec_port_binding_set_chassis(pb, NULL);
> @@ -1357,9 +1360,9 @@ claim_lport(const struct sbrec_port_binding *pb,
>              bool sb_readonly, bool is_vif,
>              struct hmap *tracked_datapaths,
>              struct if_status_mgr *if_mgr,
> -            struct sset *postponed_ports)
> +            struct sset *postponed_ports,
> +            enum can_bind can_bind)
>  {
> -    enum can_bind can_bind = lport_can_bind_on_this_chassis(chassis_rec,
> pb);
>      bool update_tracked = false;
>
>      if (can_bind == CAN_BIND_AS_MAIN) {
> @@ -1561,7 +1564,7 @@ release_binding_lport(const struct sbrec_chassis
> *chassis_rec,
>
>  static bool
>  consider_vif_lport_(const struct sbrec_port_binding *pb,
> -                    bool can_bind,
> +                    enum can_bind can_bind,
>                      struct binding_ctx_in *b_ctx_in,
>                      struct binding_ctx_out *b_ctx_out,
>                      struct binding_lport *b_lport)
> @@ -1579,7 +1582,7 @@ consider_vif_lport_(const struct sbrec_port_binding
> *pb,
>                               !b_ctx_in->ovnsb_idl_txn,
>                               !parent_pb, b_ctx_out->tracked_dp_bindings,
>                               b_ctx_out->if_mgr,
> -                             b_ctx_out->postponed_ports)) {
> +                             b_ctx_out->postponed_ports, can_bind)) {
>                  return false;
>              }
>
> @@ -1632,8 +1635,15 @@ consider_vif_lport_(const struct sbrec_port_binding
> *pb,
>                                   b_ctx_out->if_mgr);
>          }
>      }
> +
> +    struct binding_lport *parent_b_lport = b_lport && b_lport->lbinding ?
> +        local_binding_get_primary_lport(b_lport->lbinding) : NULL;
> +
>      if (pb->chassis && pb->chassis != b_ctx_in->chassis_rec
>              && !is_requested_additional_chassis(pb, b_ctx_in->chassis_rec)
> +            && (!parent_b_lport
> +                || !is_requested_additional_chassis(parent_b_lport->pb,
> +
> b_ctx_in->chassis_rec))
>              && if_status_is_port_claimed(b_ctx_out->if_mgr,
>                                           pb->logical_port)) {
>          update_lport_tracking(pb, b_ctx_out->tracked_dp_bindings, false);
> @@ -1651,7 +1661,8 @@ consider_vif_lport(const struct sbrec_port_binding
> *pb,
>                     struct binding_ctx_out *b_ctx_out,
>                     struct local_binding *lbinding)
>  {
> -    bool can_bind = lport_can_bind_on_this_chassis(b_ctx_in->chassis_rec,
> pb);
> +    enum can_bind can_bind =
> +        lport_can_bind_on_this_chassis(b_ctx_in->chassis_rec, pb);
>
>      if (!lbinding) {
>          lbinding = local_binding_find(&b_ctx_out->lbinding_data->bindings,
> @@ -1767,10 +1778,12 @@ consider_container_lport(const struct
> sbrec_port_binding *pb,
>      ovs_assert(parent_b_lport && parent_b_lport->pb);
>      /* cannot bind to this chassis if the parent_port cannot be bounded.
> */
>      /* Do not bind neither if parent is postponed */
> -    bool can_bind = lport_can_bind_on_this_chassis(b_ctx_in->chassis_rec,
> -                                                   parent_b_lport->pb) &&
> -                    !is_postponed_port(parent_b_lport->pb->logical_port)
> &&
> -                    lport_can_bind_on_this_chassis(b_ctx_in->chassis_rec,
> pb);
> +
> +    enum can_bind can_bind =
> +        (!is_postponed_port(parent_b_lport->pb->logical_port) &&
> +         lport_can_bind_on_this_chassis(b_ctx_in->chassis_rec, pb)) ?
> +         lport_can_bind_on_this_chassis(b_ctx_in->chassis_rec,
> +                                        parent_b_lport->pb) : CANNOT_BIND;
>
>      return consider_vif_lport_(pb, can_bind, b_ctx_in, b_ctx_out,
>                                 container_b_lport);
> @@ -1820,7 +1833,7 @@ consider_virtual_lport(const struct
> sbrec_port_binding *pb,
>          }
>      }
>
> -    if (!consider_vif_lport_(pb, true, b_ctx_in, b_ctx_out,
> +    if (!consider_vif_lport_(pb, CAN_BIND_AS_MAIN, b_ctx_in, b_ctx_out,
>                               virtual_b_lport)) {
>          return false;
>      }
> @@ -1916,11 +1929,13 @@ consider_nonvif_lport_(const struct
> sbrec_port_binding *pb,
>          }
>
>          update_related_lport(pb, b_ctx_out);
> +        enum can_bind can_bind = lport_can_bind_on_this_chassis(
> +                                     b_ctx_in->chassis_rec, pb);
>          return claim_lport(pb, NULL, b_ctx_in->chassis_rec, NULL,
>                             !b_ctx_in->ovnsb_idl_txn, false,
>                             b_ctx_out->tracked_dp_bindings,
>                             b_ctx_out->if_mgr,
> -                           b_ctx_out->postponed_ports);
> +                           b_ctx_out->postponed_ports, can_bind);
>      }
>      if (!is_ha_chassis) {
>          remove_related_lport(pb, b_ctx_out);
> @@ -2900,7 +2915,8 @@ handle_updated_vif_lport(const struct
> sbrec_port_binding *pb,
>      bool now_claimed = (pb->chassis == b_ctx_in->chassis_rec);
>
>      if (lport_type == LP_VIRTUAL || lport_type == LP_CONTAINER ||
> -            claimed == now_claimed) {
> +            (claimed == now_claimed &&
> +             !is_additional_chassis(pb, b_ctx_in->chassis_rec))) {
>          return true;
>      }
>
> @@ -2917,7 +2933,9 @@ handle_updated_vif_lport(const struct
> sbrec_port_binding *pb,
>      }
>
>      struct binding_lport *b_lport;
> +
>      LIST_FOR_EACH (b_lport, list_node, &lbinding->binding_lports) {
> +
>

nit: Unrelated changes.

         if (b_lport->type == LP_CONTAINER) {
>              handled = consider_container_lport(b_lport->pb, b_ctx_in,
>                                                 b_ctx_out);
> @@ -2987,7 +3005,7 @@ consider_patch_port_for_local_datapaths(const struct
> sbrec_port_binding *pb,
>                             !b_ctx_in->ovnsb_idl_txn, false,
>                             b_ctx_out->tracked_dp_bindings,
>                             b_ctx_out->if_mgr,
> -                           b_ctx_out->postponed_ports);
> +                           b_ctx_out->postponed_ports, CAN_BIND_AS_MAIN);
>      }
>      /* If this chassis is claimed, but not requested to be; or requested
> for
>       * some other chassis, but claimed by us - release. */
> diff --git a/controller/physical.c b/controller/physical.c
> index 9cab3ae26..69bf05347 100644
> --- a/controller/physical.c
> +++ b/controller/physical.c
> @@ -1773,8 +1773,8 @@ consider_port_binding(const struct physical_ctx *ctx,
>                  ctx->sbrec_port_binding_by_name, binding->parent_port);
>
>              if (parent_port
> -                && (lport_can_bind_on_this_chassis(ctx->chassis,
> -                    parent_port) != CAN_BIND_AS_MAIN)) {
> +                && !lport_can_bind_on_this_chassis(ctx->chassis,
> +                                                   parent_port)) {
>                  /* Even though there is an ofport for this container
>                   * parent port, it is requested on different chassis
> ignore
>                   * this container port.
> diff --git a/tests/multinode.at b/tests/multinode.at
> index c1bd3123a..6d0f2910d 100644
> --- a/tests/multinode.at
> +++ b/tests/multinode.at
> @@ -2776,3 +2776,260 @@ for i in 1 2; do
>  done
>
>  AT_CLEANUP
> +
> +AT_SETUP([Migration of container ports])
> +# Migrate vif port between chassis-1 and chassis-3; send packets between
> +# chassis-2 and chassis-1/chassis-3, and check that
> +# - packet handing on src works before migration.
> +# - packet handing on src & dst works during migration.
> +# - packet handing on dst works after migration.
> +# Do the same for container ports.
> +# The container port migration is tested in two different orders,
> +# setting iface-id on dst resp. before and after requested-chassis.
> +
> +# Check that ovn-fake-multinode setup is up and running
> +# check_fake_multinode_setup
> +check_fake_multinode_setup_by_nodes 'ovn-chassis-1 ovn-chassis-2
> ovn-chassis-3'
> +
> +# Delete the multinode NB and OVS resources before starting the test.
> +cleanup_multinode_resources_by_nodes 'ovn-chassis-1 ovn-chassis-2
> ovn-chassis-3'
> +
> +OVS_WAIT_UNTIL([m_as ovn-chassis-1 ip link show | grep -q genev_sys])
> +OVS_WAIT_UNTIL([m_as ovn-chassis-2 ip link show | grep -q genev_sys])
> +OVS_WAIT_UNTIL([m_as ovn-chassis-3 ip link show | grep -q genev_sys])
> +
> +check multinode_nbctl ls-add sw0
> +check multinode_nbctl lsp-add sw0 migrator
> +check multinode_nbctl lsp-set-addresses migrator "50:54:00:00:00:03
> 10.0.0.3 1000::3"
> +check multinode_nbctl lsp-add sw0 sw0-port2
> +check multinode_nbctl lsp-set-addresses sw0-port2 "50:54:00:00:00:04
> 10.0.0.4 1000::4"
> +
> +# Set requested chassis before creating migrator on chassis-3
> +check multinode_nbctl --wait=hv set Logical_Switch_Port migrator
> options:requested-chassis=ovn-chassis-1
> +
> +m_as ovn-chassis-1 /data/create_fake_vm.sh migrator migrator
> 50:54:00:00:00:03 1342 10.0.0.3 24 10.0.0.1 1000::3/64 1000::a
> +m_as ovn-chassis-3 /data/create_fake_vm.sh migrator migrator
> 50:54:00:00:00:03 1342 10.0.0.3 24 10.0.0.1 1000::3/64 1000::a
> +m_as ovn-chassis-2 /data/create_fake_vm.sh sw0-port2 sw0p2
> 50:54:00:00:00:04 1342 10.0.0.4 24 10.0.0.1 1000::4/64 1000::a
> +
> +m_wait_for_ports_up
> +
> +M_START_TCPDUMP([ovn-chassis-1], [-neei genev_sys_6081 arp or ip],
> [ch1_genev])
> +M_START_TCPDUMP([ovn-chassis-1], [-neei migrator-p arp or ip],
> [ch1_migrator])
> +M_START_TCPDUMP([ovn-chassis-2], [-neei genev_sys_6081 arp or ip],
> [ch2_genev])
> +M_START_TCPDUMP([ovn-chassis-2], [-neei sw0p2-p arp or ip], [ch2_sw0p2])
> +M_START_TCPDUMP([ovn-chassis-3], [-neei genev_sys_6081 arp or ip],
> [ch3_genev])
> +M_START_TCPDUMP([ovn-chassis-3], [-neei migrator-p arp or ip],
> [ch3_migrator])
> +
> +AS_BOX([Migration with vifs])
> +echo "Migrator on chassis-1 => sw0p2 on chassis-2"
> +M_NS_CHECK_EXEC([ovn-chassis-1], [migrator], [ping -q -c 3 -i 0.3 -w 2
> 10.0.0.4 | FORMAT_PING], \
> +[0], [dnl
> +3 packets transmitted, 3 received, 0% packet loss, time 0ms
> +])
> +
> +echo "sw0p2 on chassis-2 => Migrator on chassis-1"
> +M_NS_CHECK_EXEC([ovn-chassis-2], [sw0p2], [ping -q -c 3 -i 0.3 -w 2
> 10.0.0.3 | FORMAT_PING], \
> +[0], [dnl
> +3 packets transmitted, 3 received, 0% packet loss, time 0ms
> +])
> +
> +echo "== Starting migration =="
> +check multinode_nbctl --wait=hv set Logical_Switch_Port migrator
> options:requested-chassis=ovn-chassis-1,ovn-chassis-3
> +
> +echo "Migrator on chassis-1 => sw0p2 on chassis-2"
> +M_NS_CHECK_EXEC([ovn-chassis-1], [migrator], [ping -q -c 3 -i 0.3 -w 2
> 10.0.0.4 | FORMAT_PING], \
> +[0], [dnl
> +3 packets transmitted, 3 received, 0% packet loss, time 0ms
> +])
> +
> +
> +echo "Migrator on chassis-3 => sw0p2 on chassis-2"
> +M_NS_CHECK_EXEC([ovn-chassis-3], [migrator], [ping -q -c 3 -i 0.3 -w 2
> 10.0.0.4 | FORMAT_PING], \
> +[0], [dnl
> +3 packets transmitted, 3 received, 0% packet loss, time 0ms
> +])
> +
> +echo "sw0p2 on chassis-2 => migrator on  ..."
> +M_NS_CHECK_EXEC([ovn-chassis-2], [sw0p2], [ping -q -c 3 -i 0.3 -w 2
> 10.0.0.3 | FORMAT_PING], \
> +[0], [stdout])
> +
> +# Both VM are running ... We might get duplicates replies.
> +AT_CHECK([cat stdout | grep "3 packets transmitted" | grep -c "3
> received"], [0],[dnl
> +1
> +])
> +
> +echo "== Finalizing migration =="
> +check multinode_nbctl --wait=hv set Logical_Switch_Port migrator
> options:requested-chassis=ovn-chassis-3
> +
> +echo "Migrator on chassis-1 => sw0p2 on chassis-2"
> +M_NS_CHECK_EXEC([ovn-chassis-1], [migrator], [ping -q -c 3 -i 0.3 -w 2
> 10.0.0.4 | FORMAT_PING], \
> +[0], [stdout])
> +
> +# VM still running on chassis-1 but flows should have been deleted as
> migration completed.
> +AT_CHECK([cat stdout | grep -c "100% packet loss"], [0],[dnl
> +1
> +])
> +
> +echo "Migrator on chassis-3 => sw0p2 on chassis-2"
> +M_NS_CHECK_EXEC([ovn-chassis-3], [migrator], [ping -q -c 3 -i 0.3 -w 2
> 10.0.0.4 | FORMAT_PING], \
> +[0], [dnl
> +3 packets transmitted, 3 received, 0% packet loss, time 0ms
> +])
> +
> +# We should not have duplicates anymore
> +echo "sw0p2 on chassis-2 => migrator on chassis-2"
> +M_NS_CHECK_EXEC([ovn-chassis-2], [sw0p2], [ping -q -c 3 -i 0.3 -w 2
> 10.0.0.3 | FORMAT_PING], \
> +[0], [dnl
> +3 packets transmitted, 3 received, 0% packet loss, time 0ms
> +])
> +
> +AS_BOX([Migration with container ports])
> +# Create container ports.
> +check multinode_nbctl ls-add sw1
> +check multinode_nbctl lsp-add sw1 mig-cont migrator 10 \
> +                   -- lsp-set-addresses mig-cont "f0:00:00:01:02:03
> 20.0.0.3"
> +check multinode_nbctl lsp-add sw1 cont2 sw0-port2 10 \
> +                   -- lsp-set-addresses cont2 "f0:00:00:01:02:04 20.0.0.4"
> +
> +# Create the interface for lport mig-cont
> +M_NS_CHECK_EXEC([ovn-chassis-1], [migrator], [ip link add link migrator
> name cont type vlan id 10], [0])
> +M_NS_CHECK_EXEC([ovn-chassis-1], [migrator], [ip link set cont address
> f0:00:00:01:02:03], [0])
> +M_NS_CHECK_EXEC([ovn-chassis-1], [migrator], [ip link set cont up], [0])
> +M_NS_CHECK_EXEC([ovn-chassis-1], [migrator], [ip addr add 20.0.0.3/24
> dev cont], [0])
> +
> +M_NS_CHECK_EXEC([ovn-chassis-3], [migrator], [ip link add link migrator
> name cont type vlan id 10], [0])
> +M_NS_CHECK_EXEC([ovn-chassis-3], [migrator], [ip link set cont address
> f0:00:00:01:02:03], [0])
> +M_NS_CHECK_EXEC([ovn-chassis-3], [migrator], [ip link set cont up], [0])
> +M_NS_CHECK_EXEC([ovn-chassis-3], [migrator], [ip addr add 20.0.0.3/24
> dev cont], [0])
> +
> +# Create the interface for lport sw1-port2
> +M_NS_CHECK_EXEC([ovn-chassis-2], [sw0p2], [ip link add link sw0p2 name
> cont2 type vlan id 10], [0])
> +M_NS_CHECK_EXEC([ovn-chassis-2], [sw0p2], [ip link set cont2 address
> f0:00:00:01:02:04], [0])
> +M_NS_CHECK_EXEC([ovn-chassis-2], [sw0p2], [ip link set cont2 up], [0])
> +M_NS_CHECK_EXEC([ovn-chassis-2], [sw0p2], [ip addr add 20.0.0.4/24 dev
> cont2], [0])
> +
> +echo "mig-cont on chassis-3 => cont2 on chassis-2"
> +M_NS_CHECK_EXEC([ovn-chassis-3], [migrator], [ping -q -c 3 -i 0.3 -w 2
> 20.0.0.4 | FORMAT_PING], \
> +[0], [dnl
> +3 packets transmitted, 3 received, 0% packet loss, time 0ms
> +])
> +
> +echo "cont2 on chassis-2 => mig-count on chassis-3"
> +M_NS_CHECK_EXEC([ovn-chassis-2], [sw0p2], [ping -q -c 3 -i 0.3 -w 2
> 20.0.0.3 | FORMAT_PING], \
> +[0], [dnl
> +3 packets transmitted, 3 received, 0% packet loss, time 0ms
> +])
> +
> +echo "== Starting migration back =="
> +check multinode_nbctl --wait=hv set Logical_Switch_Port migrator
> options:requested-chassis=ovn-chassis-3,ovn-chassis-1
> +
> +echo "mig-cont on chassis-3 => cont2 on chassis-2"
> +M_NS_CHECK_EXEC([ovn-chassis-3], [migrator], [ping -q -c 3 -i 0.3 -w 2
> 20.0.0.4 | FORMAT_PING], \
> +[0], [dnl
> +3 packets transmitted, 3 received, 0% packet loss, time 0ms
> +])
> +
> +echo "mig-count on chassis-1 => cont2 on chassis-2"
> +M_NS_CHECK_EXEC([ovn-chassis-1], [migrator], [ping -q -c 3 -i 0.3 -w 2
> 20.0.0.4 | FORMAT_PING], \
> +[0], [dnl
> +3 packets transmitted, 3 received, 0% packet loss, time 0ms
> +])
> +
> +echo "cont2 on chassis-2 => migrator on  ..."
> +M_NS_CHECK_EXEC([ovn-chassis-2], [sw0p2], [ping -q -c 3 -i 0.3 -w 2
> 20.0.0.3 | FORMAT_PING], \
> +[0], [stdout])
> +
> +# Both VM are running ... We might get duplicates replies.
> +AT_CHECK([cat stdout | grep "3 packets transmitted" | grep -c "3
> received"], [0],[dnl
> +1
> +])
> +
> +echo "== Finalizing migration =="
> +check multinode_nbctl --wait=hv set Logical_Switch_Port migrator
> options:requested-chassis=ovn-chassis-1
> +
> +echo "mig-cont on chassis-3 => cont2 on chassis-2"
> +M_NS_CHECK_EXEC([ovn-chassis-3], [migrator], [ping -q -c 3 -i 0.3 -w 2
> 20.0.0.4 | FORMAT_PING], \
> +[0], [stdout])
> +
> +# VM still running on chassis-3 but flows should have been deleted....
> +AT_CHECK([cat stdout | grep -c "100% packet loss"], [0],[dnl
> +1
> +])
> +
> +echo "mig-cont on chassis-1 => cont2 on chassis-2"
> +M_NS_CHECK_EXEC([ovn-chassis-1], [migrator], [ping -q -c 3 -i 0.3 -w 2
> 20.0.0.4 | FORMAT_PING], \
> +[0], [dnl
> +3 packets transmitted, 3 received, 0% packet loss, time 0ms
> +])
> +
> +# We should not have duplicates anymore
> +echo "cont2 on chassis-2 => mig-cont on chassis-2"
> +M_NS_CHECK_EXEC([ovn-chassis-2], [sw0p2], [ping -q -c 3 -i 0.3 -w 2
> 20.0.0.3 | FORMAT_PING], \
> +[0], [dnl
> +3 packets transmitted, 3 received, 0% packet loss, time 0ms
> +])
> +
> +echo "== Starting another migration, this time before starting dst VM =="
> +# Unbind migrator from chassis-3
> +m_as ovn-chassis-3 ovs-vsctl -- set Interface migrator-p
> external_ids:iface-id=foo
> +
> +check multinode_nbctl --wait=hv set Logical_Switch_Port migrator
> options:requested-chassis=ovn-chassis-1,ovn-chassis-3
> +sleep 1
> +m_as ovn-chassis-3 ovs-vsctl -- set Interface migrator-p
> external_ids:iface-id=migrator
> +
> +
> +echo "mig-cont on chassis-3 => cont2 on chassis-2"
> +M_NS_CHECK_EXEC([ovn-chassis-3], [migrator], [ping -q -c 3 -i 0.3 -w 2
> 20.0.0.4 | FORMAT_PING], \
> +[0], [dnl
> +3 packets transmitted, 3 received, 0% packet loss, time 0ms
> +])
> +
> +echo "mig-count on chassis-1 => cont2 on chassis-2"
> +M_NS_CHECK_EXEC([ovn-chassis-1], [migrator], [ping -q -c 3 -i 0.3 -w 2
> 20.0.0.4 | FORMAT_PING], \
> +[0], [dnl
> +3 packets transmitted, 3 received, 0% packet loss, time 0ms
> +])
> +
> +echo "cont2 on chassis-2 => migrator on  ..."
> +M_NS_CHECK_EXEC([ovn-chassis-2], [sw0p2], [ping -q -c 3 -i 0.3 -w 2
> 20.0.0.3 | FORMAT_PING], \
> +[0], [stdout])
> +
> +# Both VM are running ... We might get duplicates replies.
> +AT_CHECK([cat stdout | grep "3 packets transmitted" | grep -c "3
> received"], [0],[dnl
> +1
> +])
> +
> +echo "== Finalizing migration =="
> +check multinode_nbctl --wait=hv set Logical_Switch_Port migrator
> options:requested-chassis=ovn-chassis-3
> +
> +echo "mig-cont on chassis-1 => cont2 on chassis-2"
> +M_NS_CHECK_EXEC([ovn-chassis-1], [migrator], [ping -q -c 3 -i 0.3 -w 2
> 20.0.0.4 | FORMAT_PING], \
> +[0], [stdout])
> +
> +# VM still running on chassis-1 but flows should have been deleted....
> +AT_CHECK([cat stdout | grep -c "100% packet loss"], [0],[dnl
> +1
> +])
> +
> +echo "mig-cont on chassis-3 => cont2 on chassis-2"
> +M_NS_CHECK_EXEC([ovn-chassis-3], [migrator], [ping -q -c 3 -i 0.3 -w 2
> 20.0.0.4 | FORMAT_PING], \
> +[0], [dnl
> +3 packets transmitted, 3 received, 0% packet loss, time 0ms
> +])
> +
> +# We should not have duplicates anymore
> +echo "cont2 on chassis-2 => mig-cont on chassis-2"
> +M_NS_CHECK_EXEC([ovn-chassis-2], [sw0p2], [ping -q -c 3 -i 0.3 -w 2
> 20.0.0.3 | FORMAT_PING], \
> +[0], [dnl
> +3 packets transmitted, 3 received, 0% packet loss, time 0ms
> +])
> +
> +m_as ovn-chassis-1 killall tcpdump
> +m_as ovn-chassis-2 killall tcpdump
> +m_as ovn-chassis-3 killall tcpdump
> +rm -f *.tcpdump
> +rm -f *.stderr
>

Shouldn't we keep those tcpdump logs for debugging purposes?

+
> +AT_CLEANUP
> +
> +
> diff --git a/tests/ovn.at b/tests/ovn.at
> index d105ed253..08323f372 100644
> --- a/tests/ovn.at
> +++ b/tests/ovn.at
> @@ -16785,6 +16785,160 @@ OVN_CLEANUP([hv1],[hv2])
>  AT_CLEANUP
>  ])
>
> +OVN_FOR_EACH_NORTHD([
> +AT_SETUP([No fight between two chassis for the same port])
> +ovn_start
> +
> +# lsp1 on hv1, lsp2 on hv2.
> +# migrator1 (and its mig1-cont container) initially on hv1.
> +# migrator2 (and its mig2-cont container) initially on hv2.
> +# For migrator1, iface-id is set (in both hv) before starting migration.
> +# For migrator2, iface-id is set (in dst hv) after initiating migration.
> +check ovn-nbctl ls-add ls0
> +check ovn-nbctl lsp-add ls0 lsp1
> +check ovn-nbctl lsp-add ls0 lsp2
> +check ovn-nbctl lsp-add ls0 migrator1
> +check ovn-nbctl lsp-add ls0 migrator2
> +check ovn-nbctl lsp-add ls0 mig1-cont migrator1 1
> +check ovn-nbctl lsp-add ls0 mig2-cont migrator2 1
> +check ovn-nbctl set Logical_Switch_Port migrator1
> options:requested-chassis=hv1
> +check ovn-nbctl set Logical_Switch_Port migrator2
> options:requested-chassis=hv2
> +
> +net_add n1
> +for i in 1 2; do
> +    sim_add hv$i
> +    as hv$i
> +    ovs-vsctl add-br br-phys
> +    ovn_attach n1 br-phys 192.168.0.$i
> +done
> +
> +# Set iface-id in both hv1 and hv2.
> +as hv2 ovs-vsctl -- add-port br-int vif-migrator2 \
> +                 -- set Interface vif-migrator2
> external-ids:iface-id=migrator2
> +
> +for i in 1 2; do
> +    as hv$i
> +    ovs-vsctl -- add-port br-int vif-migrator1 \
> +              -- set Interface vif-migrator1
> external-ids:iface-id=migrator1
> +    ovs-vsctl -- add-port br-int vif$i \
> +              -- set Interface vif$i external-ids:iface-id=lsp$i
> +done
> +
> +hv1_uuid=$(ovn-sbctl --bare --columns _uuid list chassis hv1)
> +hv2_uuid=$(ovn-sbctl --bare --columns _uuid list chassis hv2)
> +
> +check_in_port_flows_count() {
> +  hv=$1
> +  of=$2
> +  count=$3
> +  AT_CHECK_UNQUOTED([as $hv ovs-ofctl dump-flows br-int
> table=OFTABLE_PHY_TO_LOG | grep "in_port=$of" | wc -l], [0], [dnl
> +$count
> +])
> +}
> +
> +check_claims() {
> +    port=$1
> +    hv1_claims=$(grep -c "Claiming lport $port\|Changing chassis for
> lport $port" hv1/ovn-controller.log)
> +    hv2_claims=$(grep -c "Claiming lport $port\|Changing chassis for
> lport $port" hv2/ovn-controller.log)
> +    echo "$hv1_claims claims for port $port in hv1"
> +    echo "$hv2_claims claims for port $port in hv2"
> +    AT_CHECK([test "${hv1_claims}" -le "${max_claims}"], [0], [])
> +    AT_CHECK([test "${hv2_claims}" -le "${max_claims}"], [0], [])
> +}
> +
> +# Waiting for flows in hv1 && hv2 for resp. lsp1 and lsp2.
> +OVS_WAIT_UNTIL([
> +    of_hv1=$(as hv1 ovs-vsctl --bare --columns ofport find Interface
> name=vif1)
> +    of_hv2=$(as hv2 ovs-vsctl --bare --columns ofport find Interface
> name=vif2)
>

We can request a unique ofport number, we should probably do that instead
WDYT?


> +    test -n of_hv1 && test -n $of_hv1 &&
> +        test 1 -le $(as hv1 ovs-ofctl dump-flows br-int
> table=OFTABLE_PHY_TO_LOG | grep "in_port=$of_hv1" | wc -l) &&
> +        test 1 -le $(as hv2 ovs-ofctl dump-flows br-int
> table=OFTABLE_PHY_TO_LOG | grep "in_port=$of_hv2" | wc -l)
> +])
> +
> +of1=$(as hv1 ovs-vsctl --bare --columns ofport find Interface
> name=vif-migrator1)
> +of2=$(as hv2 ovs-vsctl --bare --columns ofport find Interface
> name=vif-migrator1)
> +
> +AS_BOX([$(date +%H:%M:%S.%03N) Before migrating migrator1])
> +wait_column "" Port_Binding additional_chassis logical_port=migrator1
> +wait_column "" Port_Binding additional_chassis logical_port=mig1-cont
> +# We should have two flows in table OFTABLE_PHY_TO_LOG from
> in_port=migrator1 in hv1 (one for vif and one for the container) and 0
> flows in hv2.
> +check_in_port_flows_count hv1 $of1 2
> +check_in_port_flows_count hv2 $of2 0
> +
> +
> +AS_BOX([$(date +%H:%M:%S.%03N) Starting migrating migrator1])
> +check ovn-nbctl --wait=hv set Logical_Switch_Port migrator1
> options:requested-chassis=hv1,hv2
> +wait_column "$hv2_uuid" Port_Binding additional_chassis
> logical_port=migrator1
> +wait_column "$hv2_uuid" Port_Binding additional_chassis
> logical_port=mig1-cont
> +# We should have two flows in table OFTABLE_PHY_TO_LOG from
> in_port=migrator1 in hv1 and hv2.
> +check_in_port_flows_count hv1 $of1 2
> +check_in_port_flows_count hv2 $of2 2
> +
> +# While migration in underway, check that there is no fight between hv
> +sleep 3
> +max_claims=2
> +check_claims migrator1
> +check_claims mig1-cont
> +
> +AS_BOX([$(date +%H:%M:%S.%03N) After migrating migrator1])
> +check ovn-nbctl --wait=hv set Logical_Switch_Port migrator1
> options:requested-chassis=hv2
> +wait_column "" Port_Binding additional_chassis logical_port=migrator1
> +wait_column "" Port_Binding additional_chassis logical_port=mig1-cont
> +check_in_port_flows_count hv1 $of1 0
> +check_in_port_flows_count hv2 $of2 2
> +
> +# Now do the same, but with iface-id set after starting migration
> +of2=$(as hv2 ovs-vsctl --bare --columns ofport find Interface
> name=vif-migrator2)
> +# There is no ofport yet for hv1 => we cannot check/find a flows with
> in_port=of1
> +
> +AS_BOX([$(date +%H:%M:%S.%03N) Before migrating migrator2])
> +# We should have zero flows in table OFTABLE_PHY_TO_LOG from
> in_port=migrator2 in hv1 and two flows in hv2.
> +wait_column "" Port_Binding additional_chassis logical_port=migrator2
> +wait_column "" Port_Binding additional_chassis logical_port=mig2-cont
> +check_in_port_flows_count hv2 $of2 2
> +
> +check ovn-nbctl --wait=hv set Logical_Switch_Port migrator2
> options:requested-chassis=hv2,hv1
> +wait_column "" Port_Binding additional_chassis logical_port=migrator2
> +wait_column "" Port_Binding additional_chassis logical_port=mig2-cont
> +# As no iface-id for migrator2 yet, migration not really started
> +# We should have zero flows in table OFTABLE_PHY_TO_LOG from
> in_port=migrator2 in hv1 and two flows in hv2.
> +check_in_port_flows_count hv2 $of2 2
> +
> +AS_BOX([$(date +%H:%M:%S.%03N) Starting migrating migrator2])
> +as hv1 ovs-vsctl -- add-port br-int vif-migrator2 \
> +                 -- set Interface vif-migrator2
> external-ids:iface-id=migrator2
> +
> +wait_column "$hv1_uuid" Port_Binding additional_chassis
> logical_port=migrator2
> +wait_column "$hv1_uuid" Port_Binding additional_chassis
> logical_port=mig2-cont
> +# We need for oflow to be created and handled by ovn-controller. Wait
> sync would not be enough.
> +OVS_WAIT_UNTIL([
> +    of1=$(as hv1 ovs-vsctl --bare --columns ofport find Interface
> name=vif-migrator2)
> +    test 1 -le "$of1"
> +])
> +
> +check ovn-nbctl --wait=hv sync
> +
> +# We should have two flows in table OFTABLE_PHY_TO_LOG from
> in_port=migrator2 in hv1 and hv2.
> +check_in_port_flows_count hv1 $of1 2
> +check_in_port_flows_count hv2 $of2 2
> +
> +# While migration in underway, check that there is no fight between hv
> +sleep 3
> +check_claims migrator2
> +check_claims mig2-cont
> +
> +AS_BOX([$(date +%H:%M:%S.%03N) After migrating migrator2])
> +check ovn-nbctl --wait=hv set Logical_Switch_Port migrator2
> options:requested-chassis=hv1
> +wait_column "" Port_Binding additional_chassis logical_port=migrator2
> +wait_column "" Port_Binding additional_chassis logical_port=mig2-cont
> +check_in_port_flows_count hv1 $of1 2
> +check_in_port_flows_count hv2 $of2 0
> +
> +OVN_CLEANUP([hv1],[hv2])
> +
> +AT_CLEANUP
> +])
> +
>  OVN_FOR_EACH_NORTHD([
>  AT_SETUP([options:requested-chassis with hostname])
>
> @@ -39199,7 +39353,7 @@ OVS_WAIT_FOR_OUTPUT([as hv2 ovs-ofctl dump-flows
> br-int table=OFTABLE_PHY_TO_LOG
>  ])
>
>  # Add hv2 to lport Additional requested chassis as MAIN chassis
> -# and check that no flows installed in table 0 in hv1
> +# and check that flows remain installed in table 0 in hv1
>  check ovn-nbctl set Logical_Switch_Port lsp1 \
>      options:requested-chassis=hv2,hv1
>
> @@ -39214,8 +39368,8 @@ wait_column "$hv2_uuid" Port_Binding chassis
> logical_port=lsp1
>  OVS_WAIT_FOR_OUTPUT([as hv2 ovs-ofctl dump-flows br-int
> table=OFTABLE_PHY_TO_LOG |grep priority=150|grep dl_vlan=7| grep -c
> in_port=8], [0],[dnl
>  1
>  ])
> -OVS_WAIT_FOR_OUTPUT([as hv1 ovs-ofctl dump-flows br-int
> table=OFTABLE_PHY_TO_LOG |grep priority=150|grep dl_vlan=7| grep -c
> in_port=8], [1],[dnl
> -0
> +OVS_WAIT_FOR_OUTPUT([as hv1 ovs-ofctl dump-flows br-int
> table=OFTABLE_PHY_TO_LOG |grep priority=150|grep dl_vlan=7| grep -c
> in_port=8], [0],[dnl
> +1
>  ])
>

This seems to be a "side effect" from the main chassis removal from
the additional chassis. If that's the case we should keep that change
separately. Would you agree?


>  OVN_CLEANUP([hv1])
> --
> 2.47.1
>
> _______________________________________________
> dev mailing list
> [email protected]
> https://mail.openvswitch.org/mailman/listinfo/ovs-dev
>
>
Thanks,
Ales
_______________________________________________
dev mailing list
[email protected]
https://mail.openvswitch.org/mailman/listinfo/ovs-dev

Reply via email to