Hi Mark Thanks for the comments/review. I'll fix those in v2.
Thanks Xavier On Mon, Feb 17, 2025 at 4:34 PM Mark Michelson <[email protected]> wrote: > Hi Xavier, I have a few findings below. > > On 2/13/25 11:01, Xavier Simonart wrote: > > Handle container ports migration in a similar way as vif migration. > > When a container port is migrated (i.e. when requested-chassis is > configured > > for its parent port), install flows in both src and dst hypervisors. > > When migration completes, remove flows from src hypervisor. > > > > Reported-at: https://issues.redhat.com/browse/FDP-1037 > > > > Signed-off-by: Xavier Simonart <[email protected]> > > --- > > controller/binding.c | 44 +++++--- > > controller/physical.c | 4 +- > > tests/multinode.at | 257 ++++++++++++++++++++++++++++++++++++++++++ > > tests/ovn.at | 160 +++++++++++++++++++++++++- > > 4 files changed, 447 insertions(+), 18 deletions(-) > > > > diff --git a/controller/binding.c b/controller/binding.c > > index 7d4143008..7f1027b02 100644 > > --- a/controller/binding.c > > +++ b/controller/binding.c > > @@ -1147,6 +1147,9 @@ set_pb_chassis_in_sbrec(const struct > sbrec_port_binding *pb, > > VLOG_INFO("%s: Claiming %s", pb->logical_port, > pb->mac[i]); > > } > > sbrec_port_binding_set_chassis(pb, chassis_rec); > > + if (is_additional_chassis(pb, chassis_rec)) { > > + remove_additional_chassis(pb, chassis_rec); > > + } > > } > > } else if (!is_set) { > > sbrec_port_binding_set_chassis(pb, NULL); > > @@ -1357,9 +1360,9 @@ claim_lport(const struct sbrec_port_binding *pb, > > bool sb_readonly, bool is_vif, > > struct hmap *tracked_datapaths, > > struct if_status_mgr *if_mgr, > > - struct sset *postponed_ports) > > + struct sset *postponed_ports, > > + enum can_bind can_bind) > > { > > - enum can_bind can_bind = > lport_can_bind_on_this_chassis(chassis_rec, pb); > > bool update_tracked = false; > > > > if (can_bind == CAN_BIND_AS_MAIN) { > > @@ -1561,7 +1564,7 @@ release_binding_lport(const struct sbrec_chassis > *chassis_rec, > > > > static bool > > consider_vif_lport_(const struct sbrec_port_binding *pb, > > - bool can_bind, > > + enum can_bind can_bind, > > struct binding_ctx_in *b_ctx_in, > > struct binding_ctx_out *b_ctx_out, > > struct binding_lport *b_lport) > > @@ -1579,7 +1582,7 @@ consider_vif_lport_(const struct > sbrec_port_binding *pb, > > !b_ctx_in->ovnsb_idl_txn, > > !parent_pb, > b_ctx_out->tracked_dp_bindings, > > b_ctx_out->if_mgr, > > - b_ctx_out->postponed_ports)) { > > + b_ctx_out->postponed_ports, can_bind)) { > > return false; > > } > > > > @@ -1632,8 +1635,15 @@ consider_vif_lport_(const struct > sbrec_port_binding *pb, > > b_ctx_out->if_mgr); > > } > > } > > + > > + struct binding_lport *parent_b_lport = b_lport && b_lport->lbinding > ? > > + local_binding_get_primary_lport(b_lport->lbinding) : NULL; > > + > > if (pb->chassis && pb->chassis != b_ctx_in->chassis_rec > > && !is_requested_additional_chassis(pb, > b_ctx_in->chassis_rec) > > + && (!parent_b_lport > > + || !is_requested_additional_chassis(parent_b_lport->pb, > > + > b_ctx_in->chassis_rec)) > > && if_status_is_port_claimed(b_ctx_out->if_mgr, > > pb->logical_port)) { > > update_lport_tracking(pb, b_ctx_out->tracked_dp_bindings, > false); > > @@ -1651,7 +1661,8 @@ consider_vif_lport(const struct sbrec_port_binding > *pb, > > struct binding_ctx_out *b_ctx_out, > > struct local_binding *lbinding) > > { > > - bool can_bind = > lport_can_bind_on_this_chassis(b_ctx_in->chassis_rec, pb); > > + enum can_bind can_bind = > > + lport_can_bind_on_this_chassis(b_ctx_in->chassis_rec, pb); > > > > if (!lbinding) { > > lbinding = > local_binding_find(&b_ctx_out->lbinding_data->bindings, > > @@ -1767,10 +1778,12 @@ consider_container_lport(const struct > sbrec_port_binding *pb, > > ovs_assert(parent_b_lport && parent_b_lport->pb); > > /* cannot bind to this chassis if the parent_port cannot be > bounded. */ > > /* Do not bind neither if parent is postponed */ > > - bool can_bind = > lport_can_bind_on_this_chassis(b_ctx_in->chassis_rec, > > - parent_b_lport->pb) > && > > - > !is_postponed_port(parent_b_lport->pb->logical_port) && > > - > lport_can_bind_on_this_chassis(b_ctx_in->chassis_rec, pb); > > + > > + enum can_bind can_bind = > > + (!is_postponed_port(parent_b_lport->pb->logical_port) && > > + lport_can_bind_on_this_chassis(b_ctx_in->chassis_rec, pb)) ? > > + lport_can_bind_on_this_chassis(b_ctx_in->chassis_rec, > > + parent_b_lport->pb) : > CANNOT_BIND; > > > > return consider_vif_lport_(pb, can_bind, b_ctx_in, b_ctx_out, > > container_b_lport); > > @@ -1820,7 +1833,7 @@ consider_virtual_lport(const struct > sbrec_port_binding *pb, > > } > > } > > > > - if (!consider_vif_lport_(pb, true, b_ctx_in, b_ctx_out, > > + if (!consider_vif_lport_(pb, CAN_BIND_AS_MAIN, b_ctx_in, b_ctx_out, > > virtual_b_lport)) { > > return false; > > } > > @@ -1916,11 +1929,13 @@ consider_nonvif_lport_(const struct > sbrec_port_binding *pb, > > } > > > > update_related_lport(pb, b_ctx_out); > > + enum can_bind can_bind = lport_can_bind_on_this_chassis( > > + b_ctx_in->chassis_rec, pb); > > return claim_lport(pb, NULL, b_ctx_in->chassis_rec, NULL, > > !b_ctx_in->ovnsb_idl_txn, false, > > b_ctx_out->tracked_dp_bindings, > > b_ctx_out->if_mgr, > > - b_ctx_out->postponed_ports); > > + b_ctx_out->postponed_ports, can_bind); > > } > > if (!is_ha_chassis) { > > remove_related_lport(pb, b_ctx_out); > > @@ -2900,7 +2915,8 @@ handle_updated_vif_lport(const struct > sbrec_port_binding *pb, > > bool now_claimed = (pb->chassis == b_ctx_in->chassis_rec); > > > > if (lport_type == LP_VIRTUAL || lport_type == LP_CONTAINER || > > - claimed == now_claimed) { > > + (claimed == now_claimed && > > + !is_additional_chassis(pb, b_ctx_in->chassis_rec))) { > > return true; > > } > > > > @@ -2917,7 +2933,9 @@ handle_updated_vif_lport(const struct > sbrec_port_binding *pb, > > } > > > > struct binding_lport *b_lport; > > + > > LIST_FOR_EACH (b_lport, list_node, &lbinding->binding_lports) { > > + > > These additional blank lines are unnecessary. > > > if (b_lport->type == LP_CONTAINER) { > > handled = consider_container_lport(b_lport->pb, b_ctx_in, > > b_ctx_out); > > @@ -2987,7 +3005,7 @@ consider_patch_port_for_local_datapaths(const > struct sbrec_port_binding *pb, > > !b_ctx_in->ovnsb_idl_txn, false, > > b_ctx_out->tracked_dp_bindings, > > b_ctx_out->if_mgr, > > - b_ctx_out->postponed_ports); > > + b_ctx_out->postponed_ports, > CAN_BIND_AS_MAIN); > > } > > /* If this chassis is claimed, but not requested to be; or > requested for > > * some other chassis, but claimed by us - release. */ > > diff --git a/controller/physical.c b/controller/physical.c > > index 9cab3ae26..69bf05347 100644 > > --- a/controller/physical.c > > +++ b/controller/physical.c > > @@ -1773,8 +1773,8 @@ consider_port_binding(const struct physical_ctx > *ctx, > > ctx->sbrec_port_binding_by_name, binding->parent_port); > > > > if (parent_port > > - && (lport_can_bind_on_this_chassis(ctx->chassis, > > - parent_port) != CAN_BIND_AS_MAIN)) { > > + && !lport_can_bind_on_this_chassis(ctx->chassis, > > + parent_port)) { > > /* Even though there is an ofport for this container > > * parent port, it is requested on different chassis > ignore > > * this container port. > > diff --git a/tests/multinode.at b/tests/multinode.at > > index c1bd3123a..6d0f2910d 100644 > > --- a/tests/multinode.at > > +++ b/tests/multinode.at > > @@ -2776,3 +2776,260 @@ for i in 1 2; do > > done > > > > AT_CLEANUP > > + > > +AT_SETUP([Migration of container ports]) > > +# Migrate vif port between chassis-1 and chassis-3; send packets between > > +# chassis-2 and chassis-1/chassis-3, and check that > > +# - packet handing on src works before migration. > > +# - packet handing on src & dst works during migration. > > +# - packet handing on dst works after migration. > > +# Do the same for container ports. > > +# The container port migration is tested in two different orders, > > +# setting iface-id on dst resp. before and after requested-chassis. > > + > > +# Check that ovn-fake-multinode setup is up and running > > +# check_fake_multinode_setup > > +check_fake_multinode_setup_by_nodes 'ovn-chassis-1 ovn-chassis-2 > ovn-chassis-3' > > + > > +# Delete the multinode NB and OVS resources before starting the test. > > +cleanup_multinode_resources_by_nodes 'ovn-chassis-1 ovn-chassis-2 > ovn-chassis-3' > > + > > +OVS_WAIT_UNTIL([m_as ovn-chassis-1 ip link show | grep -q genev_sys]) > > +OVS_WAIT_UNTIL([m_as ovn-chassis-2 ip link show | grep -q genev_sys]) > > +OVS_WAIT_UNTIL([m_as ovn-chassis-3 ip link show | grep -q genev_sys]) > > + > > +check multinode_nbctl ls-add sw0 > > +check multinode_nbctl lsp-add sw0 migrator > > +check multinode_nbctl lsp-set-addresses migrator "50:54:00:00:00:03 > 10.0.0.3 1000::3" > > +check multinode_nbctl lsp-add sw0 sw0-port2 > > +check multinode_nbctl lsp-set-addresses sw0-port2 "50:54:00:00:00:04 > 10.0.0.4 1000::4" > > + > > +# Set requested chassis before creating migrator on chassis-3 > > +check multinode_nbctl --wait=hv set Logical_Switch_Port migrator > options:requested-chassis=ovn-chassis-1 > > + > > +m_as ovn-chassis-1 /data/create_fake_vm.sh migrator migrator > 50:54:00:00:00:03 1342 10.0.0.3 24 10.0.0.1 1000::3/64 1000::a > > +m_as ovn-chassis-3 /data/create_fake_vm.sh migrator migrator > 50:54:00:00:00:03 1342 10.0.0.3 24 10.0.0.1 1000::3/64 1000::a > > +m_as ovn-chassis-2 /data/create_fake_vm.sh sw0-port2 sw0p2 > 50:54:00:00:00:04 1342 10.0.0.4 24 10.0.0.1 1000::4/64 1000::a > > + > > +m_wait_for_ports_up > > + > > +M_START_TCPDUMP([ovn-chassis-1], [-neei genev_sys_6081 arp or ip], > [ch1_genev]) > > +M_START_TCPDUMP([ovn-chassis-1], [-neei migrator-p arp or ip], > [ch1_migrator]) > > +M_START_TCPDUMP([ovn-chassis-2], [-neei genev_sys_6081 arp or ip], > [ch2_genev]) > > +M_START_TCPDUMP([ovn-chassis-2], [-neei sw0p2-p arp or ip], [ch2_sw0p2]) > > +M_START_TCPDUMP([ovn-chassis-3], [-neei genev_sys_6081 arp or ip], > [ch3_genev]) > > +M_START_TCPDUMP([ovn-chassis-3], [-neei migrator-p arp or ip], > [ch3_migrator]) > > + > > +AS_BOX([Migration with vifs]) > > +echo "Migrator on chassis-1 => sw0p2 on chassis-2" > > +M_NS_CHECK_EXEC([ovn-chassis-1], [migrator], [ping -q -c 3 -i 0.3 -w 2 > 10.0.0.4 | FORMAT_PING], \ > > +[0], [dnl > > +3 packets transmitted, 3 received, 0% packet loss, time 0ms > > +]) > > + > > +echo "sw0p2 on chassis-2 => Migrator on chassis-1" > > +M_NS_CHECK_EXEC([ovn-chassis-2], [sw0p2], [ping -q -c 3 -i 0.3 -w 2 > 10.0.0.3 | FORMAT_PING], \ > > +[0], [dnl > > +3 packets transmitted, 3 received, 0% packet loss, time 0ms > > +]) > > + > > +echo "== Starting migration ==" > > +check multinode_nbctl --wait=hv set Logical_Switch_Port migrator > options:requested-chassis=ovn-chassis-1,ovn-chassis-3 > > + > > +echo "Migrator on chassis-1 => sw0p2 on chassis-2" > > +M_NS_CHECK_EXEC([ovn-chassis-1], [migrator], [ping -q -c 3 -i 0.3 -w 2 > 10.0.0.4 | FORMAT_PING], \ > > +[0], [dnl > > +3 packets transmitted, 3 received, 0% packet loss, time 0ms > > +]) > > + > > + > > +echo "Migrator on chassis-3 => sw0p2 on chassis-2" > > +M_NS_CHECK_EXEC([ovn-chassis-3], [migrator], [ping -q -c 3 -i 0.3 -w 2 > 10.0.0.4 | FORMAT_PING], \ > > +[0], [dnl > > +3 packets transmitted, 3 received, 0% packet loss, time 0ms > > +]) > > + > > +echo "sw0p2 on chassis-2 => migrator on ..." > > +M_NS_CHECK_EXEC([ovn-chassis-2], [sw0p2], [ping -q -c 3 -i 0.3 -w 2 > 10.0.0.3 | FORMAT_PING], \ > > +[0], [stdout]) > > + > > +# Both VM are running ... We might get duplicates replies. > > +AT_CHECK([cat stdout | grep "3 packets transmitted" | grep -c "3 > received"], [0],[dnl > > +1 > > +]) > > + > > +echo "== Finalizing migration ==" > > +check multinode_nbctl --wait=hv set Logical_Switch_Port migrator > options:requested-chassis=ovn-chassis-3 > > + > > +echo "Migrator on chassis-1 => sw0p2 on chassis-2" > > +M_NS_CHECK_EXEC([ovn-chassis-1], [migrator], [ping -q -c 3 -i 0.3 -w 2 > 10.0.0.4 | FORMAT_PING], \ > > +[0], [stdout]) > > + > > +# VM still running on chassis-1 but flows should have been deleted as > migration completed. > > +AT_CHECK([cat stdout | grep -c "100% packet loss"], [0],[dnl > > +1 > > +]) > > + > > +echo "Migrator on chassis-3 => sw0p2 on chassis-2" > > +M_NS_CHECK_EXEC([ovn-chassis-3], [migrator], [ping -q -c 3 -i 0.3 -w 2 > 10.0.0.4 | FORMAT_PING], \ > > +[0], [dnl > > +3 packets transmitted, 3 received, 0% packet loss, time 0ms > > +]) > > + > > +# We should not have duplicates anymore > > +echo "sw0p2 on chassis-2 => migrator on chassis-2" > > migrator is on chassis-3. > > > +M_NS_CHECK_EXEC([ovn-chassis-2], [sw0p2], [ping -q -c 3 -i 0.3 -w 2 > 10.0.0.3 | FORMAT_PING], \ > > +[0], [dnl > > +3 packets transmitted, 3 received, 0% packet loss, time 0ms > > +]) > > + > > +AS_BOX([Migration with container ports]) > > +# Create container ports. > > +check multinode_nbctl ls-add sw1 > > +check multinode_nbctl lsp-add sw1 mig-cont migrator 10 \ > > + -- lsp-set-addresses mig-cont "f0:00:00:01:02:03 > 20.0.0.3" > > +check multinode_nbctl lsp-add sw1 cont2 sw0-port2 10 \ > > + -- lsp-set-addresses cont2 "f0:00:00:01:02:04 > 20.0.0.4" > > + > > +# Create the interface for lport mig-cont > > +M_NS_CHECK_EXEC([ovn-chassis-1], [migrator], [ip link add link migrator > name cont type vlan id 10], [0]) > > +M_NS_CHECK_EXEC([ovn-chassis-1], [migrator], [ip link set cont address > f0:00:00:01:02:03], [0]) > > +M_NS_CHECK_EXEC([ovn-chassis-1], [migrator], [ip link set cont up], [0]) > > +M_NS_CHECK_EXEC([ovn-chassis-1], [migrator], [ip addr add 20.0.0.3/24 > dev cont], [0]) > > + > > +M_NS_CHECK_EXEC([ovn-chassis-3], [migrator], [ip link add link migrator > name cont type vlan id 10], [0]) > > +M_NS_CHECK_EXEC([ovn-chassis-3], [migrator], [ip link set cont address > f0:00:00:01:02:03], [0]) > > +M_NS_CHECK_EXEC([ovn-chassis-3], [migrator], [ip link set cont up], [0]) > > +M_NS_CHECK_EXEC([ovn-chassis-3], [migrator], [ip addr add 20.0.0.3/24 > dev cont], [0]) > > + > > +# Create the interface for lport sw1-port2 > > +M_NS_CHECK_EXEC([ovn-chassis-2], [sw0p2], [ip link add link sw0p2 name > cont2 type vlan id 10], [0]) > > +M_NS_CHECK_EXEC([ovn-chassis-2], [sw0p2], [ip link set cont2 address > f0:00:00:01:02:04], [0]) > > +M_NS_CHECK_EXEC([ovn-chassis-2], [sw0p2], [ip link set cont2 up], [0]) > > +M_NS_CHECK_EXEC([ovn-chassis-2], [sw0p2], [ip addr add 20.0.0.4/24 dev > cont2], [0]) > > + > > +echo "mig-cont on chassis-3 => cont2 on chassis-2" > > +M_NS_CHECK_EXEC([ovn-chassis-3], [migrator], [ping -q -c 3 -i 0.3 -w 2 > 20.0.0.4 | FORMAT_PING], \ > > +[0], [dnl > > +3 packets transmitted, 3 received, 0% packet loss, time 0ms > > +]) > > + > > +echo "cont2 on chassis-2 => mig-count on chassis-3" > > s/mig-count/mig-cont/ > > This mistake is repeated a few times in this test. > > > +M_NS_CHECK_EXEC([ovn-chassis-2], [sw0p2], [ping -q -c 3 -i 0.3 -w 2 > 20.0.0.3 | FORMAT_PING], \ > > +[0], [dnl > > +3 packets transmitted, 3 received, 0% packet loss, time 0ms > > +]) > > + > > +echo "== Starting migration back ==" > > +check multinode_nbctl --wait=hv set Logical_Switch_Port migrator > options:requested-chassis=ovn-chassis-3,ovn-chassis-1 > > + > > +echo "mig-cont on chassis-3 => cont2 on chassis-2" > > +M_NS_CHECK_EXEC([ovn-chassis-3], [migrator], [ping -q -c 3 -i 0.3 -w 2 > 20.0.0.4 | FORMAT_PING], \ > > +[0], [dnl > > +3 packets transmitted, 3 received, 0% packet loss, time 0ms > > +]) > > + > > +echo "mig-count on chassis-1 => cont2 on chassis-2" > > +M_NS_CHECK_EXEC([ovn-chassis-1], [migrator], [ping -q -c 3 -i 0.3 -w 2 > 20.0.0.4 | FORMAT_PING], \ > > +[0], [dnl > > +3 packets transmitted, 3 received, 0% packet loss, time 0ms > > +]) > > + > > +echo "cont2 on chassis-2 => migrator on ..." > > s/migrator/mig-cont/ I think? > > > +M_NS_CHECK_EXEC([ovn-chassis-2], [sw0p2], [ping -q -c 3 -i 0.3 -w 2 > 20.0.0.3 | FORMAT_PING], \ > > +[0], [stdout]) > > + > > +# Both VM are running ... We might get duplicates replies. > > +AT_CHECK([cat stdout | grep "3 packets transmitted" | grep -c "3 > received"], [0],[dnl > > +1 > > +]) > > + > > +echo "== Finalizing migration ==" > > +check multinode_nbctl --wait=hv set Logical_Switch_Port migrator > options:requested-chassis=ovn-chassis-1 > > + > > +echo "mig-cont on chassis-3 => cont2 on chassis-2" > > +M_NS_CHECK_EXEC([ovn-chassis-3], [migrator], [ping -q -c 3 -i 0.3 -w 2 > 20.0.0.4 | FORMAT_PING], \ > > +[0], [stdout]) > > + > > +# VM still running on chassis-3 but flows should have been deleted.... > > +AT_CHECK([cat stdout | grep -c "100% packet loss"], [0],[dnl > > +1 > > +]) > > + > > +echo "mig-cont on chassis-1 => cont2 on chassis-2" > > +M_NS_CHECK_EXEC([ovn-chassis-1], [migrator], [ping -q -c 3 -i 0.3 -w 2 > 20.0.0.4 | FORMAT_PING], \ > > +[0], [dnl > > +3 packets transmitted, 3 received, 0% packet loss, time 0ms > > +]) > > + > > +# We should not have duplicates anymore > > +echo "cont2 on chassis-2 => mig-cont on chassis-2" > > mig-cont is on chassis-1. > > > +M_NS_CHECK_EXEC([ovn-chassis-2], [sw0p2], [ping -q -c 3 -i 0.3 -w 2 > 20.0.0.3 | FORMAT_PING], \ > > +[0], [dnl > > +3 packets transmitted, 3 received, 0% packet loss, time 0ms > > +]) > > + > > +echo "== Starting another migration, this time before starting dst VM > ==" > > +# Unbind migrator from chassis-3 > > +m_as ovn-chassis-3 ovs-vsctl -- set Interface migrator-p > external_ids:iface-id=foo > > + > > +check multinode_nbctl --wait=hv set Logical_Switch_Port migrator > options:requested-chassis=ovn-chassis-1,ovn-chassis-3 > > +sleep 1 > > +m_as ovn-chassis-3 ovs-vsctl -- set Interface migrator-p > external_ids:iface-id=migrator > > + > > + > > +echo "mig-cont on chassis-3 => cont2 on chassis-2" > > +M_NS_CHECK_EXEC([ovn-chassis-3], [migrator], [ping -q -c 3 -i 0.3 -w 2 > 20.0.0.4 | FORMAT_PING], \ > > +[0], [dnl > > +3 packets transmitted, 3 received, 0% packet loss, time 0ms > > +]) > > + > > +echo "mig-count on chassis-1 => cont2 on chassis-2" > > +M_NS_CHECK_EXEC([ovn-chassis-1], [migrator], [ping -q -c 3 -i 0.3 -w 2 > 20.0.0.4 | FORMAT_PING], \ > > +[0], [dnl > > +3 packets transmitted, 3 received, 0% packet loss, time 0ms > > +]) > > + > > +echo "cont2 on chassis-2 => migrator on ..." > > +M_NS_CHECK_EXEC([ovn-chassis-2], [sw0p2], [ping -q -c 3 -i 0.3 -w 2 > 20.0.0.3 | FORMAT_PING], \ > > +[0], [stdout]) > > + > > +# Both VM are running ... We might get duplicates replies. > > +AT_CHECK([cat stdout | grep "3 packets transmitted" | grep -c "3 > received"], [0],[dnl > > +1 > > +]) > > + > > +echo "== Finalizing migration ==" > > +check multinode_nbctl --wait=hv set Logical_Switch_Port migrator > options:requested-chassis=ovn-chassis-3 > > + > > +echo "mig-cont on chassis-1 => cont2 on chassis-2" > > +M_NS_CHECK_EXEC([ovn-chassis-1], [migrator], [ping -q -c 3 -i 0.3 -w 2 > 20.0.0.4 | FORMAT_PING], \ > > +[0], [stdout]) > > + > > +# VM still running on chassis-1 but flows should have been deleted.... > > +AT_CHECK([cat stdout | grep -c "100% packet loss"], [0],[dnl > > +1 > > +]) > > + > > +echo "mig-cont on chassis-3 => cont2 on chassis-2" > > +M_NS_CHECK_EXEC([ovn-chassis-3], [migrator], [ping -q -c 3 -i 0.3 -w 2 > 20.0.0.4 | FORMAT_PING], \ > > +[0], [dnl > > +3 packets transmitted, 3 received, 0% packet loss, time 0ms > > +]) > > + > > +# We should not have duplicates anymore > > +echo "cont2 on chassis-2 => mig-cont on chassis-2" > > mig-cont is on chassis-3. > > > +M_NS_CHECK_EXEC([ovn-chassis-2], [sw0p2], [ping -q -c 3 -i 0.3 -w 2 > 20.0.0.3 | FORMAT_PING], \ > > +[0], [dnl > > +3 packets transmitted, 3 received, 0% packet loss, time 0ms > > +]) > > + > > +m_as ovn-chassis-1 killall tcpdump > > +m_as ovn-chassis-2 killall tcpdump > > +m_as ovn-chassis-3 killall tcpdump > > +rm -f *.tcpdump > > +rm -f *.stderr > > + > > +AT_CLEANUP > > + > > + > > diff --git a/tests/ovn.at b/tests/ovn.at > > index d105ed253..08323f372 100644 > > --- a/tests/ovn.at > > +++ b/tests/ovn.at > > @@ -16785,6 +16785,160 @@ OVN_CLEANUP([hv1],[hv2]) > > AT_CLEANUP > > ]) > > > > +OVN_FOR_EACH_NORTHD([ > > +AT_SETUP([No fight between two chassis for the same port]) > > +ovn_start > > + > > +# lsp1 on hv1, lsp2 on hv2. > > +# migrator1 (and its mig1-cont container) initially on hv1. > > +# migrator2 (and its mig2-cont container) initially on hv2. > > +# For migrator1, iface-id is set (in both hv) before starting migration. > > +# For migrator2, iface-id is set (in dst hv) after initiating migration. > > +check ovn-nbctl ls-add ls0 > > +check ovn-nbctl lsp-add ls0 lsp1 > > +check ovn-nbctl lsp-add ls0 lsp2 > > +check ovn-nbctl lsp-add ls0 migrator1 > > +check ovn-nbctl lsp-add ls0 migrator2 > > +check ovn-nbctl lsp-add ls0 mig1-cont migrator1 1 > > +check ovn-nbctl lsp-add ls0 mig2-cont migrator2 1 > > +check ovn-nbctl set Logical_Switch_Port migrator1 > options:requested-chassis=hv1 > > +check ovn-nbctl set Logical_Switch_Port migrator2 > options:requested-chassis=hv2 > > + > > +net_add n1 > > +for i in 1 2; do > > + sim_add hv$i > > + as hv$i > > + ovs-vsctl add-br br-phys > > + ovn_attach n1 br-phys 192.168.0.$i > > +done > > + > > +# Set iface-id in both hv1 and hv2. > > Nit: Move this comment to just above the for loop. Otherwise, it looks > odd that the comment doesn't match what's being done for migrator2. > > > +as hv2 ovs-vsctl -- add-port br-int vif-migrator2 \ > > + -- set Interface vif-migrator2 > external-ids:iface-id=migrator2 > > + > > +for i in 1 2; do > > + as hv$i > > + ovs-vsctl -- add-port br-int vif-migrator1 \ > > + -- set Interface vif-migrator1 > external-ids:iface-id=migrator1 > > + ovs-vsctl -- add-port br-int vif$i \ > > + -- set Interface vif$i external-ids:iface-id=lsp$i > > +done > > + > > +hv1_uuid=$(ovn-sbctl --bare --columns _uuid list chassis hv1) > > +hv2_uuid=$(ovn-sbctl --bare --columns _uuid list chassis hv2) > > + > > +check_in_port_flows_count() { > > + hv=$1 > > + of=$2 > > + count=$3 > > + AT_CHECK_UNQUOTED([as $hv ovs-ofctl dump-flows br-int > table=OFTABLE_PHY_TO_LOG | grep "in_port=$of" | wc -l], [0], [dnl > > +$count > > +]) > > +} > > + > > +check_claims() { > > + port=$1 > > + hv1_claims=$(grep -c "Claiming lport $port\|Changing chassis for > lport $port" hv1/ovn-controller.log) > > + hv2_claims=$(grep -c "Claiming lport $port\|Changing chassis for > lport $port" hv2/ovn-controller.log) > > + echo "$hv1_claims claims for port $port in hv1" > > + echo "$hv2_claims claims for port $port in hv2" > > + AT_CHECK([test "${hv1_claims}" -le "${max_claims}"], [0], []) > > + AT_CHECK([test "${hv2_claims}" -le "${max_claims}"], [0], []) > > +} > > + > > +# Waiting for flows in hv1 && hv2 for resp. lsp1 and lsp2. > > +OVS_WAIT_UNTIL([ > > + of_hv1=$(as hv1 ovs-vsctl --bare --columns ofport find Interface > name=vif1) > > + of_hv2=$(as hv2 ovs-vsctl --bare --columns ofport find Interface > name=vif2) > > + test -n of_hv1 && test -n $of_hv1 && > > + test 1 -le $(as hv1 ovs-ofctl dump-flows br-int > table=OFTABLE_PHY_TO_LOG | grep "in_port=$of_hv1" | wc -l) && > > + test 1 -le $(as hv2 ovs-ofctl dump-flows br-int > table=OFTABLE_PHY_TO_LOG | grep "in_port=$of_hv2" | wc -l) > > +]) > > + > > +of1=$(as hv1 ovs-vsctl --bare --columns ofport find Interface > name=vif-migrator1) > > +of2=$(as hv2 ovs-vsctl --bare --columns ofport find Interface > name=vif-migrator1) > > + > > +AS_BOX([$(date +%H:%M:%S.%03N) Before migrating migrator1]) > > +wait_column "" Port_Binding additional_chassis logical_port=migrator1 > > +wait_column "" Port_Binding additional_chassis logical_port=mig1-cont > > +# We should have two flows in table OFTABLE_PHY_TO_LOG from > in_port=migrator1 in hv1 (one for vif and one for the container) and 0 > flows in hv2. > > +check_in_port_flows_count hv1 $of1 2 > > +check_in_port_flows_count hv2 $of2 0 > > + > > + > > +AS_BOX([$(date +%H:%M:%S.%03N) Starting migrating migrator1]) > > +check ovn-nbctl --wait=hv set Logical_Switch_Port migrator1 > options:requested-chassis=hv1,hv2 > > +wait_column "$hv2_uuid" Port_Binding additional_chassis > logical_port=migrator1 > > +wait_column "$hv2_uuid" Port_Binding additional_chassis > logical_port=mig1-cont > > +# We should have two flows in table OFTABLE_PHY_TO_LOG from > in_port=migrator1 in hv1 and hv2. > > +check_in_port_flows_count hv1 $of1 2 > > +check_in_port_flows_count hv2 $of2 2 > > + > > +# While migration in underway, check that there is no fight between hv > > +sleep 3 > > +max_claims=2 > > +check_claims migrator1 > > +check_claims mig1-cont > > + > > +AS_BOX([$(date +%H:%M:%S.%03N) After migrating migrator1]) > > +check ovn-nbctl --wait=hv set Logical_Switch_Port migrator1 > options:requested-chassis=hv2 > > +wait_column "" Port_Binding additional_chassis logical_port=migrator1 > > +wait_column "" Port_Binding additional_chassis logical_port=mig1-cont > > +check_in_port_flows_count hv1 $of1 0 > > +check_in_port_flows_count hv2 $of2 2 > > + > > +# Now do the same, but with iface-id set after starting migration > > +of2=$(as hv2 ovs-vsctl --bare --columns ofport find Interface > name=vif-migrator2) > > +# There is no ofport yet for hv1 => we cannot check/find a flows with > in_port=of1 > > + > > +AS_BOX([$(date +%H:%M:%S.%03N) Before migrating migrator2]) > > +# We should have zero flows in table OFTABLE_PHY_TO_LOG from > in_port=migrator2 in hv1 and two flows in hv2. > > +wait_column "" Port_Binding additional_chassis logical_port=migrator2 > > +wait_column "" Port_Binding additional_chassis logical_port=mig2-cont > > +check_in_port_flows_count hv2 $of2 2 > > + > > +check ovn-nbctl --wait=hv set Logical_Switch_Port migrator2 > options:requested-chassis=hv2,hv1 > > +wait_column "" Port_Binding additional_chassis logical_port=migrator2 > > +wait_column "" Port_Binding additional_chassis logical_port=mig2-cont > > +# As no iface-id for migrator2 yet, migration not really started > > +# We should have zero flows in table OFTABLE_PHY_TO_LOG from > in_port=migrator2 in hv1 and two flows in hv2. > > +check_in_port_flows_count hv2 $of2 2 > > + > > +AS_BOX([$(date +%H:%M:%S.%03N) Starting migrating migrator2]) > > +as hv1 ovs-vsctl -- add-port br-int vif-migrator2 \ > > + -- set Interface vif-migrator2 > external-ids:iface-id=migrator2 > > + > > +wait_column "$hv1_uuid" Port_Binding additional_chassis > logical_port=migrator2 > > +wait_column "$hv1_uuid" Port_Binding additional_chassis > logical_port=mig2-cont > > +# We need for oflow to be created and handled by ovn-controller. Wait > sync would not be enough. > > +OVS_WAIT_UNTIL([ > > + of1=$(as hv1 ovs-vsctl --bare --columns ofport find Interface > name=vif-migrator2) > > + test 1 -le "$of1" > > +]) > > + > > +check ovn-nbctl --wait=hv sync > > + > > +# We should have two flows in table OFTABLE_PHY_TO_LOG from > in_port=migrator2 in hv1 and hv2. > > +check_in_port_flows_count hv1 $of1 2 > > +check_in_port_flows_count hv2 $of2 2 > > + > > +# While migration in underway, check that there is no fight between hv > > +sleep 3 > > +check_claims migrator2 > > +check_claims mig2-cont > > + > > +AS_BOX([$(date +%H:%M:%S.%03N) After migrating migrator2]) > > +check ovn-nbctl --wait=hv set Logical_Switch_Port migrator2 > options:requested-chassis=hv1 > > +wait_column "" Port_Binding additional_chassis logical_port=migrator2 > > +wait_column "" Port_Binding additional_chassis logical_port=mig2-cont > > +check_in_port_flows_count hv1 $of1 2 > > +check_in_port_flows_count hv2 $of2 0 > > + > > +OVN_CLEANUP([hv1],[hv2]) > > + > > +AT_CLEANUP > > +]) > > + > > OVN_FOR_EACH_NORTHD([ > > AT_SETUP([options:requested-chassis with hostname]) > > > > @@ -39199,7 +39353,7 @@ OVS_WAIT_FOR_OUTPUT([as hv2 ovs-ofctl dump-flows > br-int table=OFTABLE_PHY_TO_LOG > > ]) > > > > # Add hv2 to lport Additional requested chassis as MAIN chassis > > -# and check that no flows installed in table 0 in hv1 > > +# and check that flows remain installed in table 0 in hv1 > > check ovn-nbctl set Logical_Switch_Port lsp1 \ > > options:requested-chassis=hv2,hv1 > > > > @@ -39214,8 +39368,8 @@ wait_column "$hv2_uuid" Port_Binding chassis > logical_port=lsp1 > > OVS_WAIT_FOR_OUTPUT([as hv2 ovs-ofctl dump-flows br-int > table=OFTABLE_PHY_TO_LOG |grep priority=150|grep dl_vlan=7| grep -c > in_port=8], [0],[dnl > > 1 > > ]) > > -OVS_WAIT_FOR_OUTPUT([as hv1 ovs-ofctl dump-flows br-int > table=OFTABLE_PHY_TO_LOG |grep priority=150|grep dl_vlan=7| grep -c > in_port=8], [1],[dnl > > -0 > > +OVS_WAIT_FOR_OUTPUT([as hv1 ovs-ofctl dump-flows br-int > table=OFTABLE_PHY_TO_LOG |grep priority=150|grep dl_vlan=7| grep -c > in_port=8], [0],[dnl > > +1 > > ]) > > > > OVN_CLEANUP([hv1]) > > _______________________________________________ dev mailing list [email protected] https://mail.openvswitch.org/mailman/listinfo/ovs-dev
