On Wed, Aug 28, 2019 at 03:26:31PM +0800, kai xi fan wrote: > There is no limit on the number of packet in message send to controller > now. > We have faced a lots of problems for this when user is doing ip scanning. > ovs will send a packet in message to controller after table lookup miss. > I think that it's better to take the design from hardware switch asic: ovs > could limit the packet in message number by input port, table and bridge.
OVS has had this feature for over 10 years. _______________________________________________ discuss mailing list [email protected] https://mail.openvswitch.org/mailman/listinfo/ovs-discuss