I'm writing for design help.

Briefly there are some settings, like "overdrive" and some of the
"flex-time" parameters that pertain to individual adapters.
There are 2 alternatives:
1. List them only in the specific bus.n directory
2. List them in the main directory as "overdrive.0, overdrive.1, ...
We currently do the second way, sort of.

The current setup for root directories is:
devices (e.g. 10.67C6697351FF)
uncached
simultaneous
alarm
structure
settings
statistics
bus.0
bus.1
...
system


Now "uncached" is more of a flag.

"Simultaneous" and "alarm" are special directories generated by device
conditions.

"Structure" shows the framework of supported devices and their properties
and properties' properties. It is global.

"Settings" shows/sets time limits and temperature scale. Global (we could
have different timeouts for each adapter, but we don't currently).

"Statistics" shows things such as read and write counts, bytes transfered,
error counts. Some is bus-specific (statistics/bus) and the rest is global.

"System" has
adapter information (system/adapter) Process information
-------------------------------------------------------------------------