Dear Paul,
>Also comparing your circuit with the one on page 25 of the DS2480B manual
>http://datasheets.maxim-ic.com/en/ds/DS2480B.pdf
>you have the POL pin at ground, and they have it at +VDD. Could you have
>polarity reversed?
The RS232 level converter normally work inverted. Please also take a look at
page 25 of the SD2480B manual. The POL pin apparently needs to be connected to
ground. I will give a shot though, and test.
> Also I'm embarrassed to admit that msec_read is no longer implemented
> (despite being in the man page). It is now --timeout_serial
> As just the easiest test, can you try with that parameter? (Still, using
> your exact command line worked for me as well).
Result as expected -- no change in behavior.
Did Michael is dongle to work ? If so, do you happen to know what he did to
make it work ?
Thanks
Tilman