Just to answer this as well, I did have the TAI8558 powered externally, 
but, as you pointed out, it's probably the cabling itself.

Chris.

Paul Alfille wrote:
> The AAG microhub (DS2409-based) humidity probe (DS2438 based) and 
> barometer (DS2406x2) all work perfectly with OWFS.
>
> The TAI8558 http://www.aagelectronica.com/pdf%20docs/TAI_8558.pdf is a 
> DS2408, but looks like it needs to be powered, or have something done 
> with JP1.
>
> The TAI8555 
> http://www.aagelectronica.com/pdf%20docs/tai8555%20switch%20(ingles).pdf 
> <http://www.aagelectronica.com/pdf%20docs/tai8555%20switch%20%28ingles%29.pdf>
>  
> is DS2406 based, doesn't seem to touch the power line, and should have 
> no issues.
>
> Do either of the AAG items work individually?
>
> Paul Alfille
> ------------------------------------------------------------------------
>
> -------------------------------------------------------------------------
> This SF.net email is sponsored by: Microsoft
> Defy all challenges. Microsoft(R) Visual Studio 2008.
> http://clk.atdmt.com/MRT/go/vse0120000070mrt/direct/01/
> ------------------------------------------------------------------------
>
> _______________________________________________
> Owfs-developers mailing list
> [email protected]
> https://lists.sourceforge.net/lists/listinfo/owfs-developers
>   

-------------------------------------------------------------------------