Hi,

I tried to get my setups from 2.7p21 (cvs-snapshot from 2009-06-04) to the 
current CVS-version.
Now this still gives me two big problems:

1. reconnecting the DS9490 doesn't work anymore, this worked with p21 (even 
though not under all circumstances). I have to admit this matters only on lousy 
buses, i.e. too long, but I have one bus "maxed out" as far as possible to be 
able to do some regression-testing on what could happen in the field..
With p21 owserver syslogged "reconnecting bad adapter" (max: 32/hour) and 
things were fine, in p27 all devices disapear, requests hang forever..

2. when owserver hangs (i.e. by removing the USB-adapter physically), any 
request to it with owget (or similar) hangs forever. The previous behaviour, 
return nothing, was much better IMHO..

I created some workaround in my logger-app now, restarting owserver when an 
81.xx adapter disappears but that's probably no real solution..


Please let me know if I should create debug-logs, and if yes which. It's 
currently reproducable, although not within minutes..


best regards 

Michael

------------------------------------------------------------------------------