Hi Guys, Several of my DS28EA00 sensors have a Solid State Relay connected to one of the PIO outputs, which drives a water circulating pump in my underfloor heating system. I've just been experimenting with controlling the PIO outputs to control the pumps but I notice that when temploggerd does a scan, the PIO output driving the pump resets and turns the pump off.
I've isolated this PIO reset to the writing of a 1 to simultaneous/temperature. By commenting out the simultaneous/temperature line in the temploggerd config it stops resetting the PIOs but now the scan takes much longer. Any ideas what might be causing this and how I might fix it? Regards Alex Shepherd ------------------------------------------------------------------------------ ThinkGeek and WIRED's GeekDad team up for the Ultimate GeekDad Father's Day Giveaway. ONE MASSIVE PRIZE to the lucky parental unit. See the prize list and enter to win: http://p.sf.net/sfu/thinkgeek-promo _______________________________________________ Owfs-developers mailing list Owfs-developers@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/owfs-developers