Yes, Roberto - the DS18B20 datasheet is very definite that the Vdd pin must
be connected to the ground pin if the chip is to be used in parasitic mode.
If it is to be used in powered mode then Vdd must be connected to +5V.
On Fri, Mar 11, 2011 at 06:52, <
[email protected]> wrote:
> From: Roberto Spadim <[email protected]>
> what the best method to use parasite? put +5v pin to ground? it will
> not float :)
> that?s the best method?
>
>
------------------------------------------------------------------------------