yes hehe my is the second, i connect 5v, 0v and owbus
does ds18b20 have a crc or another feature that shows the reset status
or something else? i could check for example....
read 85 degree
read the crc value (or another reset value)
start of infinite loop:
   read 85 degree again
   read the crc value (or another reset value)
if crc value = reset value, loop, else good read

i don't know if exists a reset counter or something like it in
ds18b20, does anyone know?


Em 29 de fevereiro de 2012 23:07, Eloy Paris <[email protected]> escreveu:
> Hi Roberto,
>
>
> On 02/29/2012 08:31 PM, Roberto Spadim wrote:
>
>> hi guys, i'm having a lot of problem with ds18b20 and 85 degree reads
>> what are every body doing when this occur?
>> today i read to times when this occur, and if it's 85 em both i allow 85
>> degree
>> anyone know another good solution?
>
>
> If parasitic powered make sure that Vdd is connected to ground instead of
> leaving it floating. If they are being powered then I am afraid I don't have
> a good suggestion :-(
>
> Cheers,
>
> Eloy Paris.-
>
>
>



-- 