the new logic could be:
start loop:
start conversion
read scratch
if we don't have a 85degree exit loop
else, we got a 85 degree...
read rom
check if rom and scratch value are =, if not exit loop (we have a
real 85 degree)
if they are "=" we have a reseted device... :(
change current temphigh value to eprom -1 (may be we may need
to use temp low +1, if temp high = the highest value....)
return to start
------------------------------------------------------------------------------