the new logic could be:

start loop:
start conversion
read scratch
if we don't have a 85degree exit loop
else, we got a 85 degree...
    read rom
    check if rom and scratch value are =, if not exit loop (we have a
real 85 degree)

     if they are "=" we have a reseted device... :(
         change current temphigh value to eprom -1 (may be we may need
to use temp low +1, if temp high = the highest value....)
         return to start

------------------------------------------------------------------------------
Virtualization & Cloud Management Using Capacity Planning
Cloud computing makes use of virtualization - but cloud computing 
also focuses on allowing computing to be delivered as a service.
http://www.accelacomm.com/jaw/sfnl/114/51521223/
_______________________________________________
Owfs-developers mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/owfs-developers

Reply via email to