Hello,

It's probably not an owfs problem, but perhaps people here have some
experience with the new humidity sensor from Hobby Boards.  It seems to
work fine with the latest owserver, but the readings seem a bit low.
It's heavy fog and rain outside (i.e. 100%), but I only get 80-85%.  The
temperature is about 5C.  Indoor I got about 40% which probably is about
right, so it does react to humidity.  Has anyone seen something similar?

Also, the temperature reading is about one degree C higher than the
DS1820 sensors I have at the same place.  Does it generate internal
heat?  I'm using the standard HB enclosure.  The venting holes do seem a
bit small.

An issue which is owfs related: Is it possible to change the polling
frequency?

# owget -s 3000 /EF.90A020150000/humidity/polling_available
         255
# owget -s 3000 EF.90A020150000/humidity/polling_frequency
           2
# owwrite -s 3000 EF.90A020150000/humidity/polling_frequency 1
# owget -s 3000 EF.90A020150000/humidity/polling_frequency
           2

Shouldn't this work?

-- 
Steinar

------------------------------------------------------------------------------
_______________________________________________
Owfs-developers mailing list
Owfs-developers@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/owfs-developers

Reply via email to