Hello, It's probably not an owfs problem, but perhaps people here have some experience with the new humidity sensor from Hobby Boards. It seems to work fine with the latest owserver, but the readings seem a bit low. It's heavy fog and rain outside (i.e. 100%), but I only get 80-85%. The temperature is about 5C. Indoor I got about 40% which probably is about right, so it does react to humidity. Has anyone seen something similar?
Also, the temperature reading is about one degree C higher than the DS1820 sensors I have at the same place. Does it generate internal heat? I'm using the standard HB enclosure. The venting holes do seem a bit small. An issue which is owfs related: Is it possible to change the polling frequency? # owget -s 3000 /EF.90A020150000/humidity/polling_available 255 # owget -s 3000 EF.90A020150000/humidity/polling_frequency 2 # owwrite -s 3000 EF.90A020150000/humidity/polling_frequency 1 # owget -s 3000 EF.90A020150000/humidity/polling_frequency 2 Shouldn't this work? -- Steinar ------------------------------------------------------------------------------ _______________________________________________ Owfs-developers mailing list Owfs-developers@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/owfs-developers