Am 05.11.2016 um 21:54 schrieb Enrico Hoepfner:
> Hello Jan,
> 
> Thank you for the answer!
> 
>   I have 4 buses because
> 1) DS18B20 an DS2408 need different pullup-resistors
>
How? Both should be fine with 1.5k to 3.3V.


> 2) the 4 buses goes to different locations
>
Star topology. Okay.


>
> I dont understand why owfs is checking presence of the device of all 
> buses - seems like owserver has forgotten where the device is connected 
> and check all buses, if there is presence this one.
>
This is a deliberate choice. Owfs does not remember where a device was
connected. Because it could have been moved since last access. It's up
to the application to keep track.

Kind regards

        Jan

------------------------------------------------------------------------------