Hi Jan,

Many thanks for your words of wisdom, I will take them on board.

You say that the DS2482-800 can reset to an unusable state, would the same apply to the DS2482-100?  Sheepwalk now make a dual channel RPi2 and I could stack 2 to get 4 channels and I think I could manage with that if the lock up problem is fixed.

Thanks

Mick

On 20/10/2018 18:00, Jan Kandziora wrote:

About the bus lock-up, that's a bug in the DS2482-800, I think. I had
it. Various other people had it. The DS2482-800 seems to be susceptible
to supply undervoltage and slow rising of the supply voltage. It resets
into an unuseable state. Only a complete power-down and quick power-on
will make it useable again.

Kind regards

        Jan



_______________________________________________
Owfs-developers mailing list
Owfs-developers@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/owfs-developers