Am 20.10.18 um 22:01 schrieb Mick Sulley:
> 
> You say that the DS2482-800 can reset to an unusable state, would the
> same apply to the DS2482-100?  Sheepwalk now make a dual channel RPi2
> and I could stack 2 to get 4 channels and I think I could manage with
> that if the lock up problem is fixed.
> 
We haven't had the same complaints from people using the DS2482-100 on
this list yet. If I remember correctly.

But personally, I hadn't got the lockup problem either once the power
supply problems were fixed. Check your power supply.

Kind regards

        Jan