Update on test findings.  Test setup was 19 - DS18B20 temperature, 2 - DS2413 IO and 1 - DS2437 Voltage, Raspberry Pi4 with Sheepwalk RPi3 Adapter

1) /simultaneous/temperature does work, best to read latesttemp.

2) /settings/timeout/presence cannot be set or read via the owhttpd web page, you must use owwrite & owread

3) Reading values (after setting simultaneous) normally takes < 0.1 seconds

4) After the /settings/timeout/presence interval the next read for every device will take around 0.7 seconds.  Note if you read multiple fields it is only the first one which takes the increased time.

5) The increased time after /settings/timeout/presence interval applies to all devices, not just temperature


Mick