Hi Marko,

On 09/12/2012 07:39 AM, Marko Mrvelj wrote:
> Hi,
> 
> So far it seems to work, but I still need to do more intensive testing. I 
> only saw problem when PF is trying to instruct Switch to change VLAN on a 
> port (I guess this is SNMP problem).
> 
> My Cisco has firmware version 12.2(58)SE2. I think it's not firmware 
> related. As described in network devices configuration, ifindex of 
> Gi0/1…Gi0/48 -> 10101…10148 while Fa0/1…Fa0/48 -> 10001…10048.  2960 has 
> most of ports Fa and only few Gi, while 2960G is all Gi (see snmpwalk below)

Can you tell me if you see lines like these in your logs/packetfence.log
file?

WARN: Unknown NAS-Port format. ifIndex translation could have failed.
VLAN re-assignment and switch/port accounting will be affected.

Oh and I just pushed a new 2960G module which does exactly the same
thing as the 3560G one.

Cheers!

-- 
Olivier Bilodeau
[email protected]  ::  +1.514.447.4918 *115  ::  www.inverse.ca
Inverse inc. :: Leaders behind SOGo (www.sogo.nu) and PacketFence
(www.packetfence.org)

------------------------------------------------------------------------------