The issue is just when you disconnect the device, right ?
So let's say you plug a device who is unreg in the switch port, what
happen, does it go in the registration vlan ?
If it's the case then it's not really an issue since the port need to be
authenticate to packetfence to provide access.
Regards
Fabrice
Le 19-05-06 à 05 h 06, Adrian Dessaigne via PacketFence-users a écrit :
Hello Fabrice,
I've configured two port with the same 802.1X configuration but one
with ADAC and one without ADAC,
Both have the same issues, when disconnecting the device, it won't go
back to the registration VLAN.
Adrian.
------------------------------------------------------------------------
*De: *"packetfence-users" <packetfence-users@lists.sourceforge.net>
*À: *"packetfence-users" <packetfence-users@lists.sourceforge.net>
*Cc: *"Durand fabrice" <fdur...@inverse.ca>
*Envoyé: *Vendredi 3 Mai 2019 03:34:35
*Objet: *Re: [PacketFence-users] Avaya ERS 3500 Vlan issue
It looks to be a switch issue.
When the device disconnect there is no radius request so no vlan returned.
Did you check if it's not from the ADAC config ?
Regards
Fabrice
Le 19-04-30 à 04 h 06, Adrian Dessaigne via PacketFence-users a écrit :
Hello Nicolas,
Here is the RADIUS Request and response :
User-Name = "host/DESKTOP-JO52C5K.novasys.local"
NAS-IP-Address = 192.168.X.X
NAS-Port = 17
Service-Type = Framed-User
Framed-MTU = 1490
State = 0xebf974efeafe6e4ea33e40492859bead
Calling-Station-Id = "c8:d9:d2:ec:65:2d"
NAS-Port-Type = Ethernet
Event-Timestamp = "janv. 1 1970 01:00:00 CET"
EAP-Message = 0x020700061a03
FreeRADIUS-Proxied-To = 127.0.0.1
EAP-Type = MSCHAPv2
Stripped-User-Name = "host/DESKTOP-JO52C5K.novasys.local"
Realm = "null"
PacketFence-Domain = "AD1"
User-Password = "******"
SQL-User-Name = "host/DESKTOP-JO52C5K.novasys.local"
MS-MPPE-Encryption-Policy = Encryption-Required
MS-MPPE-Encryption-Types = 4
MS-MPPE-Send-Key = 0xc37cc8ada8b87872458222dadcfa6551
MS-MPPE-Recv-Key = 0x1e5de1c194966c8931fda0ade5819882
EAP-Message = 0x03070004
Message-Authenticator = 0x00000000000000000000000000000000
User-Name = "host/DESKTOP-JO52C5K.novasys.local"
Tunnel-Type = VLAN
Tunnel-Private-Group-Id = "1001"
Tunnel-Medium-Type = IEEE-802
Do PacketFence logs when devices leave the network ?
Best Regards,
Adrian
------------------------------------------------------------------------
*De: *"packetfence-users" <packetfence-users@lists.sourceforge.net>
*À: *"packetfence-users" <packetfence-users@lists.sourceforge.net>
*Cc: *"Nicolas Quiniou-Briand" <n...@inverse.ca>
*Envoyé: *Lundi 29 Avril 2019 14:27:49
*Objet: *Re: [PacketFence-users] Avaya ERS 3500 Vlan issue
Hello Adrian,
1. What PacketFence displays in Audit log for a RADIUS request
sent by
your Avaya switch ?
--
Nicolas Quiniou-Briand
n...@inverse.ca :: +1.514.447.4918 *140 :: https://inverse.ca
Inverse inc. :: Leaders behind SOGo (https://sogo.nu), PacketFence
(https://packetfence.org) and Fingerbank (http://fingerbank.org)
_______________________________________________
PacketFence-users mailing list
PacketFence-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/packetfence-users
_______________________________________________
PacketFence-users mailing list
PacketFence-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/packetfence-users
_______________________________________________
PacketFence-users mailing list
PacketFence-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/packetfence-users
_______________________________________________
PacketFence-users mailing list
PacketFence-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/packetfence-users