Oops. That is exactly what I intended with the patch I gave you, but I made a goof. I guess I should have actually tried it before sending it off.
It's a simple fix. I just needed to add a line. The newly attached patch should work. I actually tried it before sending this time. :) -Ken On 9/18/09 9:05 AM, "Karl König" <[email protected]> wrote: Ken, Thanks for looking into it again. But your patch does less than mine (not only in terms of changed lines :-) ). Loading e.g. the file series sampleinputfiles/withduplicatetimes[0-9].foo with "Ignore Reader Time" unchecked, the information tab lists the following time indices and times: Idx Val 0 0 1 0.1 2 0.3 3 0.4 4 0.8 5 0.9 That's fine, that's default behaviour. The files withduplicatetimes{1,4,5,6}.foo are ignored. With "Ignore Reader Time" checked, the information tab does not list any time index/value any more and only the last file of the series gets loaded: sampleinputfiles/withduplicatetimes9.foo. So, one cannot step through the intermediate results for a given time step value any more. Applying my patch, the information tab lists (in case "Ignore Reader Time" is checked) all 10 files with fake time step values: Idx Val 0 0 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 and one can really step through all files of the series. Karl ----- Original Message ----- From: "Moreland, Kenneth" <[email protected]> To: Karl König <[email protected]> CC: "[email protected]" <[email protected]> Sent: 09/18/09 16:19:37 Subject: [Paraview] Problem with custom time-aware reader > Karl, > > Your patch seems overly complicated. There is exactly one check in > vtkFileSeriesReader to determine whether the internal reader has time, > and that is in RequestInformation. It is a lot less intrusive to just > add a condition to that check there. I've attached a patch that > implements the no-time flag in this way. (BTW, I changed the name from > IgnoreTimeStepValues to IgnoreReaderTime since a reader can in fact > specify time without specifying time steps.) > > -Ken > > > On 9/18/09 4:47 AM, "Karl König" <[email protected]> wrote: > > Hi, > > I dug deeper into the class FileSeriesReader and found out that despite > what I thought and posted earlier everything is already there to be able > to implement a toggle to use/ignore time step values contained in a file > series. I'd like to propose the attached patch. It can be tested with > the attached minimal time series reader plugin, sample input files are > contained. The plugin's server manager XML has been extended to expose > the IgnoreTimeStepValues checkbox provided by the patched class > FileSeriesReader. > > I don't see the patch interfering with existing readers relying on class > FileSeriesReader. > Any thoughts? > > Thanks in advance for feedback, > Karl > > > > **** Kenneth Moreland > *** Sandia National Laboratories > *********** > *** *** *** email: [email protected] > ** *** ** phone: (505) 844-8919 > *** web: http://www.cs.unm.edu/~kmorel > **** Kenneth Moreland *** Sandia National Laboratories *********** *** *** *** email: [email protected] ** *** ** phone: (505) 844-8919 *** web: http://www.cs.unm.edu/~kmorel
vtkFileSeriesReader.patch
Description: vtkFileSeriesReader.patch
_______________________________________________ Powered by www.kitware.com Visit other Kitware open-source projects at http://www.kitware.com/opensource/opensource.html Please keep messages on-topic and check the ParaView Wiki at: http://paraview.org/Wiki/ParaView Follow this link to subscribe/unsubscribe: http://www.paraview.org/mailman/listinfo/paraview