Have a look at [vcf~], set the resonance with the first parameter and the cutoff frequency with a signal to the 2nd inlet.
Cheers, Joe On 2 September 2011 18:57, Menno van der Woude <[email protected]> wrote: > Hi all, > > working on patches that will be controlled by video analysis (through > OSC messages), I am wondering how to change the frequency (second > inlet) for [bp~] in realtime. > The problem is: connecting a [line] object or number object to this > inlet will result in clicks and pops when the line is moving very fast > or changes are rapid. > > Is there a way to change the frequency for [bp~] at sample rate? > Or should I use another object to achieve this kind of realtime > cutoff/resonance changes? > I kind of like the simplicity of [bp~] as opposed to for example > [cpole~], which is beyond my current grasp of this material... > > Thanks, menno > > _______________________________________________ > [email protected] mailing list > UNSUBSCRIBE and account-management -> > http://lists.puredata.info/listinfo/pd-list >
_______________________________________________ [email protected] mailing list UNSUBSCRIBE and account-management -> http://lists.puredata.info/listinfo/pd-list