On 03/16/2016 02:25 PM, i go bananas wrote:
> thanks Iohannes. it seems the inlets are fine,. and it's just an issue with
> the outlets, and probably a problem with me not being able to wrap my head
> around that weird clockwise outlet creation thing, and perhaps also this
> other issue of pd using the same address for inlets and outlets as an
> optimisation?

most likely the latter.

> 
> i have now managed to get the external working, by changing the order of
> outlet creation in tilde_dsp, that makes the outlets backwards.

as claude has pointed out, this is not a fix, and just waits to break on
next usage.
which signals get re-used is a function of the surrounding patch, and
unrelated to the creation order within the object's dsp-function.


msd
IOhannes

Attachment: signature.asc
Description: OpenPGP digital signature

_______________________________________________
[email protected] mailing list
UNSUBSCRIBE and account-management -> 
http://lists.puredata.info/listinfo/pd-list

Reply via email to