In a message dated 2004-12-23 12:19:13 PM Eastern Standard Time, 
[EMAIL PROTECTED] writes:


> 1) Anybody seen anything like this before? or can come up with an sequence
> of steps that may have caused this?
> 
> 2) Its going to take a long time to check every part in the design. Anybody
> have any suggestions for finding further errors?
> 

Easy enough to do. Either load the part manually, or have it in the schematic 
as 0603 and later change to 1206, and forget to check the box to update part 
footprints.

I'd just reload the netlist, being sure to check the two boxes (and 
thereafter reselect the netlist file - they do it backwards). Then clean up the 
resulting DRC errors, and you should be home.

Steve Hendrix
 
____________________________________________________________
You are subscribed to the PEDA discussion forum

To Post messages:
mailto:[email protected]

Unsubscribe and Other Options:
http://techservinc.com/mailman/listinfo/peda_techservinc.com

Browse or Search Old Archives (2001-2004):
http://www.mail-archive.com/[email protected]
 
Browse or Search Current Archives (2004-Current):
http://www.mail-archive.com/[email protected]