On Mon, March 13, 2006 2:17 pm, Chris Ridd wrote: > (Adrian sent me the debug output direct.) > > It looks quite like the server was sending mangled BER. The LDAP result > was > actually very large (so the byte offsets logged were OK), but the server > suddenly decided to send a PrintableString value instead of an OCTET > STRING > value, and it got even more confused from there on...
Hm, that alone should not cause an issue. I was expecting some length byte to be wrong. Chris, can you forward the packet to me, I would like to take a look too. Graham.