On 12/10/12 11:06 PM, Sean Farley wrote: > On Mon, Dec 10, 2012 at 10:40 PM, Jed Brown <jedbrown at mcs.anl.gov> wrote: >> On Mon, Dec 10, 2012 at 8:36 PM, Barry Smith <bsmith at mcs.anl.gov> wrote: >>> >>> I'd the ability to provide to TS a list of times at which I'd like the >>> ODE integrator have exactly match that time on a time-step (that is adjust >>> the delta t near that time to hit it exactly). This is something Shri >>> needs. >> >> >> Is this general enough to add to the library itself? > > What Barry is describing is what I've asked for before when revamping > the TS interface. It's a dead-simple feature: you just pass a list of > times. It shouldn't require monkeying around with the adaptive > controller
Sean, do you need it to stop times or produce the solution at given? The solution can be produced via interpolation (would be relatively easy to implement - Matlab does that). We need to be careful about stopping - there could be situations in which we have to take a step(s) of [small number]*epsilon machine that in turn may lead to instabilities. -Emil