Hi, I just noticed pgAdmin cannot set value of sequence to start with 1 because generates SQL like this: SELECT setval('"MySchema"."MySequence"', 1, true);
it is not possible to set "is_called" option of setval to false. According to doc ( http://www.postgresql.org/docs/9.1/static/functions-sequence.html): * "If it is set to false, the next nextval will return exactly the specified value, and sequence advancement commences with the following nextval"* so, please add checkbox in sequence properties to allow to modify this switch. thanks & regards, Bartek