Hi, On Thu, Oct 29, 2026 at 03:52:46PM +0530, vignesh C wrote: > There is the following documentation mentioning that slots must be > created with the same parameters of the subscription at [1]. > When altering the slot_name, the failover and two_phase property > values of the named slot may differ from the counterpart failover and > two_phase parameters specified in the subscription. When creating the > slot, ensure the slot properties failover and two_phase match their > counterpart parameters of the subscription. Otherwise, the slot on the > publisher may behave differently from what these subscription options > say: for example, the slot on the publisher could either be synced to > the standbys even when the subscription's failover option is disabled > or could be disabled for sync even when the subscription's failover > option is enabled. > > I'm not sure if this should be handled here as it is documented already.
I agree about the documentation, but the patch introduces a regression: without the patch, two_phase is enabled on the replacement slot. With the patch, it remains disabled. It might be worth fixing, as preserving 'e' only when slot_name is unchanged should be simple enough. Regards, -- Bertrand Drouvot PostgreSQL Contributors Team RDS Open Source Databases Amazon Web Services: https://aws.amazon.com