Hi, On Thu, Oct 29, 2026 at 03:04:12PM +0800, Zhijie Hou wrote: > Agreed. I adjusted the test order to make it clear. > > Here is the V2 patch.
Thanks for the patch! + /* + * Change system catalog accordingly, but do not reset the + * state to PENDING if two_phase is already enabled. + */ + if (!(opts.twophase && + sub->twophasestate == LOGICALREP_TWOPHASE_STATE_ENABLED)) The new condition also preserves 'e' when slot_name changes. In that case, a replacement slot with two_phase=false remains false because the worker does not go through the PENDING state. I reproduced this with: ALTER SUBSCRIPTION sub SET (slot_name = 'replacement', two_phase = true); Should we preserve 'e' only when the slot name is unchanged? Regards, -- Bertrand Drouvot PostgreSQL Contributors Team RDS Open Source Databases Amazon Web Services: https://aws.amazon.com