I have been using the IRBlaster plugin, v4.1.2, to try and learn the IR
codes for an X10 ir7243 device. This is an infrared to X10 controller.
I have already taught my Pronto 950 the commands and it works fine when
I use that directly. However, the IR emitter [from an MCE remote]
plugged into my Squeezebox3 does not work when sending these commands.
I have used the plugin in learning mode to generate the following
file:
Code:
--------------------
begin remote
name X10
flags RAW_CODES
begin raw_codes
name 1
4350 3725 1250 3750
3725 3750 1250 6425
3725 3750 1250 3750
4300 3750 1250 3750
3725 3750 1250 20000
name 2
3725 3750 1250 3750
3725 3750 1250 3750
3725 3750 1250 3750
3725 3750 1250 3750
3725 3750 1250 3750
name on
4350 3700 1275 6375
3725 3725 1250 3725
3725 3725 1250 6375
3725 3725 1250 3700
4300 3725 1250 20000
name off
4350 3725 1250 3725
3725 3725 1250 3700
4300 3725 1250 3725
3725 3725 1250 3700
4300 3725 1250 20000
end raw_codes
end remote
--------------------
When I power on or off my Squeezebox the IR emitter has a single flash
which looks identical to me whether I turn it on or off, so presumably
it is sending the commands OK. So this may mean it is not learning the
codes correctly to start with.
Do my raw_codes look legitimate? BTW I'm running SlimServer Version:
6.5.2 - 11665.
Thanks.
Edit:
Forgot to mention that I have command '2' followed by either 'on' or
'off' as the commands being sent with a 1 second delay. This X10
command is used to power on/off my Aego-M 2.1 speakers plugged into an
X10 appliance module.
--
mattross
------------------------------------------------------------------------
mattross's Profile: http://forums.slimdevices.com/member.php?userid=8434
View this thread: http://forums.slimdevices.com/showthread.php?t=34523