Pokersut;451851 Wrote: 
> Tried it - but still no luck!
> 
> I have also tried it with the new LIRC protocol, but that doesn't work
> either. Strangely, though, when I assign an IR-command to a button (e.g.
> Play), it loses it's original function - and I did remember to put an
> '@' in front of the DATA_PRESS command.
> 
> So status as of now is that this works (dang, those LIRC codes are long
> ...!):
> 
> > 
Code:
--------------------
  >   > ROOT ; ACTION ; ON/OFF ; ON ; OFF ; 
LIRC:35000:9038:4332:675:1556:675:454:662:0xE13E:16:0xA45B:16:100,,,,,,,,,,,,LIRC:35000:9038:4332:675:1556:675:454:662:0xE13E:16:0xD926:16:100
  ; LIRC:35000:9038:4332:675:1556:675:454:662:0xE13E:16:0x13EC:16:100
--------------------
> > 
> 
> but this doesn't:
> 
> > 
Code:
--------------------
  >   > ROOT ; KEY ; KEY_PLAY ; ON ; ; 
@LIRC:35000:9038:4332:675:1556:675:454:662:0xE13E:16:0xA45B:16:100,,,,,,,,,,,,LIRC:35000:9038:4332:675:1556:675:454:662:0xE13E:16:0xD926:16:100
 ;
--------------------
> > 
> 
> The only difference between them is that TYPE changes from ACTION to
> KEY, and TITLE changes accordingly. Also, the DATA_HOLD command is
> removed from the KEY command.
> 
> Any idea why this does not work?
> 
> 
> 
> And also the strings.txt file (it wouldn't be too much of a hassle to
> re-create that one, but still)
> 
> 
> 
> Cool - thanks!
I didn't think the LIRC commands would work if the hex parameters still
had the '0x' bit at the start but I stand corrected - the SBC must be
cleverer than I thought!
Your lines should work, I tried them on my system (had to replace your
ir commands with something my kit would recognise and it worked fine
although I didn't have the '@' prefix. I'll try it with that later
tonight.  Is it just the play key that doesn't work or does everything
in SqueezeIR stop working when you put that line into your file? 
Without sounding stupid, but just to make sure, the play key is the one
with the right-arrow on it, top right of the wheel.

Can you put the line 'DEBUG 1' into your squeezeirdata.txt and try
again, then PM me the log file from the SBC?  I forget where the log
file is stored exactly but will find out.

The LIRC codes are long but need to encapsulate all the protocol
information aswell as the actual codes hence the number of parameters
needed, and the reason why 'proper' protocols are better (but only if
you know them) as a lot of the info can be coded into the applet.

Why do you say you need to backup stings.txt? Have I forgotten to
include it with RC2?


-- 
indifference_engine
------------------------------------------------------------------------
indifference_engine's Profile: 
http://forums.slimdevices.com/member.php?userid=20698
View this thread: http://forums.slimdevices.com/showthread.php?t=66795

_______________________________________________
plugins mailing list
[email protected]
http://lists.slimdevices.com/mailman/listinfo/plugins

Reply via email to