> The script itsself is stored in a file, but I call it from the 
hooks 
> list. 

Right, so a script in memory is executing (and calling a script in a 
file, but it is still running till that file script returns).


>> Also, pressing apply doesn't crash it.

I think reason is due to the sequence of events as follows:
1.  Press OK on pproconf.
2.  Config window is closed.
3.  windows system sends message to powerpro that window event has 
happened and hook script starts
4.  config program finishes processing ok button and sends message to 
powerpro.exe to restart with new pcf file.  This happens while in-
memory script starting in 3 is still running
5.  Crash.

For apply, the config window is not closed, so 3-5 do not happen.

ONe can think of possible ways to work around this, but they either 
involve redesigns of config (do step 4 before 2 in above) or chance 
of other timing errors.  I have not plans to try them for now.





> Your workaround seems to be fine, is there a way to make the config 
> dialog start with a specific command list selected though? Like 
when 
> you click on configure in command list context menu.

following on one line

start /wait "" "c:/program files/powerpro/pproconf.exe" ?
commandlists "?clistname"

You'd have to pass clistname to batch file as parameter if it varied.

>


Reply via email to