North Anna's provides the following response:

We have very few electronic dosimeter alarm "spikes" due to the strong EMF 
generated during welding activities.  But some newly purchased bolt heating 
equipment caused several issues with the DMC-2000S at one of our sister 
stations.  We ordered some of the DMC-2000 SOR/Rs to test and evaluate prior to 
our refueling outage.  We had no dosimeter spikes with the DMC-2000 SOR/Rs 
after rigorous testing with various EMF fields from welding equipment, heaters, 
motors, and transformers, etc.

Similar to Palo Verde, we found that the military version of the DMC-2000S, the 
SOR/R is not susceptible due to the way the antenna is constructed and placed 
inside the dosimeter.  We tested this against both EMF and EMI fields at our 
sites.  In addition, the display screen was easier to see by our workforce.

Hope this helps!


Barbara J. Thompson
Supervisor of Exposure Control
Dominion - North  Anna Power Station
Email:  [email protected]
Phone:  540-894-2605
Beeper: #3469
FAX:  540-894-2408


From: [email protected] [mailto:[email protected]] On Behalf Of 
Whitener, Christopher A
Sent: Thursday, September 09, 2010 7:34 AM
To: [email protected]
Subject: Powernet: Welding Electronic Dosimeter?

Duke E nergy would appreciate any input for the following:
Is anyone using an electronic dosimeter specifically for welding (special RF 
shielding)?


Email Firewall made the following annotations
---------------------------------------------------------------------
--- NOTICE ---
This message is for the designated recipient only and may contain confidential, 
privileged or proprietary information. If you have received it in error, please 
notify the sender immediately and delete the original and any copy or printout. 
Unintended recipients are prohibited from making any other use of this e-mail. 
Although we have taken reasonable precautions to ensure no viruses are present 
in this e-mail, we accept no liability for any loss or damage arising from the 
use of this e-mail or attachments, or for any delay or errors or omissions in 
the contents which result from e-mail transmission.
---------------------------------------------------------------------


CONFIDENTIALITY NOTICE:  This electronic message contains
information which may be legally confidential and or privileged and
does not in any case represent a firm ENERGY COMMODITY bid or offer
relating thereto which binds the sender without an additional
express written confirmation to that effect.  The information is
intended solely for the individual or entity named above and access
by anyone else is unauthorized.  If you are not the intended
recipient, any disclosure, copying, distribution, or use of the
contents of this information is prohibited and may be unlawful.  If
you have received this electronic transmission in error, please
reply immediately to the sender that you have received the message
in error, and delete it.  Thank you.

Reply via email to