Answers for Diablo Canyon are below:

During in-processing, do you utilize a software system that automatically 
prints out labels for dosimetry worn?
No, but we are going to this with our next software upgrade in September 2011.

Approximately how many people do you badge that never go into the radiological 
area?
We have really worked on this in the past few years and our numbers have 
reduced.  It's still in the 25% range of the folks who receive no measurable 
dose.

How many TLD's does your site issue per year?
Depends on how many outages per year.
2010 - a one outage year - about 3000.  Of those, approximately 1500 receive no 
measurable dose
2009 - a two outage year - about 4100.  Of those, approximately 1700 received 
no measurable dose

How often does your site do a TLD change out? (quarterly, semi-annual, 
annually, etc.)
3 times per year, at various times based on outage schedules.

What kind of dosimetry badges does your site use? (TLD, OSL, etc.)
Panasonic

Do you process your own dosimetry?
Yes

Happy Friday and Memorial Day weekend all!!!

Linda

Linda M. Sewell, CHP
Principal Health Physicist
Pacific Gas & Electric Company
Diablo Canyon Power Plant
MS 119/1/117
PO Box 56
Avila Beach, CA 93424

P: 805.545.4315 | F: 805.545.2618| [email protected]

________________________________
From: [email protected] [mailto:[email protected]] On Behalf Of 
Kelton, Gwenna
Sent: Thursday, May 26, 2011 11:36 AM
To: '[email protected]'
Subject: Powernet: Dosimetry Benchmarking

 Please respond to questions below:


  1.  During in-processing, do you utilize a software system that automatically 
prints out labels for dosimetry worn?
  2.  Approximately how many people do you badge that never go into the 
radiological area?
  3.  How many TLD's does your site issue per year?
  4.  How often does your site do a TLD change out? (quarterly, semi-annual, 
annually, etc.)
  5.  What kind of dosimetry badges does your site use? (TLD, OSL, etc.)
  6.  Do you process your own dosimetry?