Fort Calhoun Station completed Nuclear Steam Supply System Refurbishment 
Project (NSSSRP) to include SGR, Reactor Head and Pressurizer replacement for 
274.205 person-rem.  Balance of plant work was 81.593 person-rem, NSSSR Project 
was 192.612 person-rem for the total mentioned above of 274.205 person-rem.  
This work was performed in the fall of 2006.

Thanks, Anne Lollis, Supervisor-ALARA, Fort Calhoun Station

From: [email protected] [mailto:[email protected]] On Behalf Of 
Rouse, Raymond Lawrence
Sent: Monday, July 11, 2011 1:28 PM
To: [email protected]
Subject: Powernet: IER 11-1

Watts Bar is addressing this IER.


IER L2 11-1 - Inadequate Collective Radiation Exposure Performance Improvements

Summary

During the past five years, the trend for reducing collective radiation 
exposure (CRE) has not been acceptable.  Several units remain well over the 
current industry CRE goal and have not made significant progress toward 
reducing collective dose.  The boiling water reactors as a group did not meet 
the 2010 CRE annualized cycle dose goal of less than120 person-rem.  Two major 
causes of high collective dose were elevated radioactive source terms and 
shortfalls in outage dose reduction planning and work execution.  Weaknesses in 
organizational support and prioritization of initiatives were the underlying 
contributors to the problems.

Actions

*       Self-assessments are to be completed within 150 days of the issue date 
of this document.

*       INPO is to be informed of the self-assessment report and action plans 
within 210 days of the issue date of this document.
This announcement was sent to Site Vice Presidents; it was also sent to Plant 
Managers, Administrative Points of Contact, INPO Coordinators, Operating 
Experience Coordinators, Performance Improvement and Corrective Action 
Contacts, Nuclear Network Coordinators, and Analysis Review Board.

If you have questions or inquiries, please contact Amanda Donges, section 
manager, Events Analysis at (770) 644-8175, [email protected].


Although this is mainly directed at BWRs as PWRs we must show want we have done 
to make the expectation.

Radiologically significant outages in recent years has been and Steam Generator 
Replacement.

Watts Bars wants to know:

Watts Bar is looking for stations that have performed Steam Generator 
Replacements in recent years and for what dose they completed the project with?

Watts Bar replaced generators in 2006 for 306.337 Man Rem with 436,639 Man Rem.



Raymond Rouse
Health Physicist
Watts Bar Nuclear Plant
PO Box 2000
Spring City, Tn 37381
(423)-365-1881
[email protected]<mailto:[email protected]>

----------------------------------------------------------------------
This e-mail contains Omaha Public Power District's confidential and proprietary 
information and is for use only by the intended recipient.  Unless explicitly 
stated otherwise, this e-mail is not a contract offer, amendment, nor 
acceptance.  If you are not the intended recipient you are notified that 
disclosing, copying, distributing or taking any action in reliance on the 
contents of this information is strictly prohibited.

Reply via email to