The Trojan experience with EDM was the same as San Onofre. Trojan used EDM for an upflow modification requiring numerous 3" diameter holes in the top core plate. The clean up system was woefully inadequate and we had high activity corrision product hot particles for years after. The clean up system is the most important. I recommend doing some mockup testing of the clean up/filtration system to ensure it will actually collect the debris.
Tom Meek
(Trojan RPM when it existed)

On 4/11/2012 8:23 AM, [email protected] wrote:
Hi Barbara, many, many moons ago, we (San Onofre) did EDM on the fuel alignment plate. Not the same as your work on the alignment pins but still EDM on highly activated material. The main thing I recall was that in spite of all the efforts to ensure aggressive underwater vacuuming for debris, there was significant material (discrete particles) remaining on the cavity floor that presented contamination control challenges when the work was complete and equipment was being removed from the pool. And then again once drained down and conducting final cavity cleaning. I don't recall any airborne issues because the particles were "large." Hope that helps. Eric

Eric M. Goldin, CHP
Southern California Edison
<[email protected]>



From: BJ Thompson <[email protected]>
To: "[email protected]" <[email protected]>
Date: 04/10/2012 02:12 PM
Subject: Powernet: Underwater EDM on Primary Components (Quick Benchmark)
Sent by: [email protected]
------------------------------------------------------------------------




We are preparing to inspect and possible repair a bent alignment pin on our Upper Internals package. Is there any OE you would like to share on contamination controls, airborne radioactivity, high activity particle generation, etc.

Thanks for your fast feedback!


Barbara J. Thompson
Supervisor of Exposure Control
Dominion - North  Anna Power Station
Email: [email protected]_ <mailto:[email protected]>
Phone:  540-894-2605
Beeper: #3469
FAX:  540-894-2408

*CONFIDENTIALITY NOTICE:* This electronic message contains information which may be legally confidential and/or privileged and does not in any case represent a firm ENERGY COMMODITY bid or offer relating thereto which binds the sender without an additional express written confirmation to that effect. The information is intended solely for the individual or entity named above and access by anyone else is unauthorized. If you are not the intended recipient, any disclosure, copying, distribution, or use of the contents of this information is prohibited and may be unlawful. If you have received this electronic transmission in error, please reply immediately to the sender that you have received the message in error, and delete it. Thank you.