Hey Dave, We use PADS but the data is pulled down by a bridge program and put in SENTINEL for us. As long as it's in PADS. We have a lot of short term workers from other sites, etc. that are not in PADS for dose because they haven't been terminated.
That being said, we don't necessarily require PADS verification prior to TLD issue. We do require the individual to fill out and sign a Form 4 equivalent and sign for the current years dose. Normally, RP techs don't issue TLDs, but are trained and capable. Only the dosimetry staff is PADS qualified. Fred Rosser RP Specialist Grand Gulf Nuclear Station 601-437-6571 From: [email protected] [mailto:[email protected]] On Behalf Of Dave Raye Sent: Tuesday, December 23, 2014 5:19 PM To: [email protected] Subject: Powernet: TLD issue and PADs use. EXTERNAL SENDER. DO NOT click links if sender is unknown. DO NOT provide your user ID or password. Hello all, Currently, at Cook we have incoming radworkers document and attest to their current year dose. We then validate this attestation with PADs immediately, before issuing the TLD (following WBC). Does your site require that current year dose be validated on PADs prior to TLD issue? Does your site allow issue of a TLD without validating current year dose beyond attestation w/ signature?. If your RP Techs issue TLDs after hours, are the PADs qualified? Please feel free to add any additional info as you see fit. Thank you all, Dave Raye RP Operations Gen Supv Cook Nuclear Plant 269-466-2803 (O) 269-405-6040 (C) 2803 pager