At Vogtle 1&2 the FSAR contains the statement "that any area found contaminated 
is roped off or otherwise delineated with a physical barrier, posted with 
appropriate signs, and decontaminated as soon as practicable.  In areas where 
the radiation level is high or where it is considered impractical to 
decontaminate the area to general radiation controlled area limits, a step-off 
pad is used to prevent the spread of contamination." This seems to contains 
more detail than necessary and requires a swing gate or rope at the 
ingress/egress area. The practice was questioned by INPO at boundaries in which 
a rope was utilized as the barrier.
Question: Does your utility have that much detail in your FSAR for 
contamination control?

Michelle Williams
RP Superintendent Support Services
Plant Vogtle Units 1&2
706.848.4236 tel
919.770.7138 cell
[southern_nucl_h_rgb]