Adam:  The ISOCS InSitu gamma spec system has been frequently used for this 
kind of application - quantifying the gamma activity [or the upper bounds of 
non-activity] in heat exchangers, scaffolding bundles, pipe bundles, ... at D&D 
project, or Large Component replacement projects.

Frazier Bronson  CHP
Mirion Technologies - Canberra

From: Hall, Adam R [mailto:[email protected]]
Sent: Tuesday, February 06, 2018 5:39 PM
To: '[email protected]'
Subject: [powernet] condenser tube change out PWR

We are changing out our main turbine condenser tubes at Waterford 3 next 
January.  Has any other PWR done this?  Did you do any verification that they 
were not rad material?  If so what did you do?  We had small primary to 
secondary leaks a long time ago.

Thanks,
Adam Hall
Radwaste Specialist
Waterford 3
504-464-3200
[Image result for radwaste 
cartoon]<https://www.google.com/url?q=https://www.dreamstime.com/stock-illustration-cartoon-hazmat-waste-illustration-man-suit-barrel-radioactive-image47714317&sa=U&ved=0ahUKEwit5-uE_I7XAhWH7YMKHYmaCbcQwW4IFjAA&usg=AOvVaw37epVjwHWQ-VjfVfXn1WbA>

Reply via email to