Does anyone have specific procedures to allow the opening of RAM & Contaminated Equipment Packages outside to allow for Security Inspections? Do you require material to inside a building for these inspections?
INPO 05-008 §RP.4-5 appears to make allowances for this: "Appropriate controls are used when radioactive material containers are opened in nonradiologically (sic) controlled areas for special situations, such as security inspections. A policy is established that containers holding radioactive materials should only be opened in radiologically controlled areas. In situations in which this cannot be met, controls are established that require management approval to allow inspections outside the RCA. The process includes controls, designated locations and expectations to minimize the potential effects of the spread of contamination or unplanned dose". However, outside observers have indicated that this is not standard industry practice. Thanks John Diehl, CHP South Texas Projection Health Physics 361-972-8545
_______________________________________________ Powernet mailing list [email protected] http://hpspowernet.org/mailman/listinfo/powernet_hpspowernet.org