[ https://issues.apache.org/jira/browse/PROTON-401?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=13814034#comment-13814034 ]
Ted Ross commented on PROTON-401: --------------------------------- If there is a way for the Engine user to determine the drain mode of a sender, I believe I can solve my problem. > Ordering issue prevents credit drain from working properly > ---------------------------------------------------------- > > Key: PROTON-401 > URL: https://issues.apache.org/jira/browse/PROTON-401 > Project: Qpid Proton > Issue Type: Bug > Components: proton-c > Affects Versions: 0.5 > Reporter: Ken Giusti > Assignee: Rafael H. Schloming > Fix For: 0.6 > > Attachments: drain-error.patch, drain-hack.patch > > > If the sending link calls pn_link_drained() to indicate that it has send all > pending data, and afterwards it receives a Flow frame with drain=true from > the peer, then the drain never completes. > The ordering is the problem: if the flow frame w/drain=true is received > _BEFORE_ the sender calls pn_link_drained(), then it works. -- This message was sent by Atlassian JIRA (v6.1#6144)