You should be able to use pn_link_get_drain(sender) to determine the drain
mode of a sender.


On Tue, Nov 5, 2013 at 11:50 AM, Ted Ross (JIRA) <[email protected]> wrote:

>
>     [
> https://issues.apache.org/jira/browse/PROTON-401?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=13814034#comment-13814034]
>
> Ted Ross commented on PROTON-401:
> ---------------------------------
>
> If there is a way for the Engine user to determine the drain mode of a
> sender, I believe I can solve my problem.
>
> > Ordering issue prevents credit drain from working properly
> > ----------------------------------------------------------
> >
> >                 Key: PROTON-401
> >                 URL: https://issues.apache.org/jira/browse/PROTON-401
> >             Project: Qpid Proton
> >          Issue Type: Bug
> >          Components: proton-c
> >    Affects Versions: 0.5
> >            Reporter: Ken Giusti
> >            Assignee: Rafael H. Schloming
> >             Fix For: 0.6
> >
> >         Attachments: drain-error.patch, drain-hack.patch
> >
> >
> > If the sending link calls pn_link_drained() to indicate that it has send
> all pending data, and afterwards it receives a Flow frame with drain=true
> from the peer, then the drain never completes.
> > The ordering is the problem: if the flow frame w/drain=true is received
> _BEFORE_ the sender calls pn_link_drained(), then it works.
>
>
>
> --
> This message was sent by Atlassian JIRA
> (v6.1#6144)
>

Reply via email to